2.  Installation 

 

CAUTION:

 

Circuit devices are sensitive to static electricity, which can damage their delicate 

electronics. Dry weather conditions or walking across a carpeted floor may cause you to acquire a static 

electrical charge. To protect your device, always: 

 

Touch the metal chassis of your computer to ground the static electrical charge before you pick up the 

circuit device. 

 

Pick up the device by holding it on the left and right edges only. 

 

If you need to connect an outdoor device to this device with cable then you must add an arrester on 

the cable between outdoor device and this device.

 

 

Fig. Add an arrester between outdoor device and this switch 

 

N

OTE

:

   

The switch is an indoor device; if it will be used in an outdoor environment or 

connects with some outdoor device, then it must use a lightning arrester to protect the switch.

 

 

W

ARNING

:

 

 

 

Self-demolition on Product is strictly prohibited. Damage caused by self-demolition will be charged 

for repairing fees.   

 

Do not place product outdoors or where sandstorms occur. 

 

Before installation, make sure input power supply and product specifications are compatible to each 

other. 

 

To reduce the risk of electric shock, disconnect all AC or DC power cords to completely remove 

power from the unit. 

 

Before importing / exporting configuration please make sure the firmware version is the same.   

 

After firmware upgrade, switch automatically moves configuration to latest firmware version.

 

Warning

: this case must be grounded. No DC input may be grounded. The SM24TAT2DPA is compliant with 802.3at 

in Environment A when using an isolated power supply. For 802.3at Environment B applications, use mid-span injector 
(s), e.g. MIL-L100i, L1000i-at, between this switch’s PSE port and link partner PD port. 

 

Summary of Contents for SM24TAT2DPA

Page 1: ...Transition Networks SM24TAT2DPA Install Guide 33702 Rev A https www transition com Page 1 of 23 SM24TAT2DPA Managed Switch 24 port Gigabit PoE 2 port SFP RJ 45 Combo Install Guide 33702 Rev A...

Page 2: ...l hazard that could cause loss of data or damage the system or equipment SM24TAT2DPA Install Guide TN PN 33702 Rev A Record of Revisions Rev Date Description of Changes A 11 7 16 Initial release for s...

Page 3: ...for RJ 45 connections Category 3 or better for 10 Mbps connections Category 5 or better for 100 Mbps connections Category 5 5e or 6 for 1000 Mbps connections For fiber optic connections you may use 5...

Page 4: ...Back Panel 8 2 Installation 9 Package Contents 10 Mounting the Switch in a 19 inch Rack 11 Mounting the Switch on Desk or Shelf 12 Connecting the AC Power Cord 12 Installing SFP Modules 13 Connecting...

Page 5: ...n and troubleshooting and the Mode Reset button The SM24TAT2DPA front panel is shown and described below LED Descriptions The LEDs on the front panel provide users with switch status checking and moni...

Page 6: ...e Mode Reset button When Link Act Speed Mode LED Lit LED Color State Description RJ45 Ports Green On The port is enabled and established a link to connected device and the connection speed is 1000Mbps...

Page 7: ...for a specific period of time to perform these tasks Change Port Status LED Mode to read the port status correctly in the two different modes Link Act Speed mode or PoE mode Reset the Switch to reboot...

Page 8: ...Transition Networks SM24TAT2DPA Install Guide 33702 Rev A https www transition com Page 8 of 23 Back Panel The SM24TAT2DPA back panel is shown below...

Page 9: ...an outdoor environment or connects with some outdoor device then it must use a lightning arrester to protect the switch WARNING Self demolition on Product is strictly prohibited Damage caused by self...

Page 10: ...ition com Page 10 of 23 Package Contents Verify that you received these iterms SM24TAT2DPA GbE Management Switch Four adhesive rubber feet Mounting Accessory for 19 Rack Shelf Optional Quick Start Gui...

Page 11: ...s to both sides of the chassis with screws Figure 4 Attaching mounting brackets to the switch Step2 Place the switch on a rack shelf in the rack Push the switch in until the oval holes in the brackets...

Page 12: ...e accessory kit Attach the four adhesive rubber feet to the bottom of the switch Figure 6 Attaching the Rubber Feet Connecting the AC Power Cord Figure 7 Connecting the AC power cord to the AC power r...

Page 13: ...n SFP module DMI DDMI data etc Step1 Insert the module into the switch port The SFP label must be facing upward on the top port the SFP label must be facing downward on the bottom port Step2 Press fir...

Page 14: ...P address for example for a PC running Windows 7 8 x 10 is as follows Step 1 Type network and sharing into the Search box in the Start Menu Step 2 Select Network and Sharing Center Step 3 Click on Cha...

Page 15: ...e is an IP conflict issue Clean browser cookies and temporary Internet files Check your PC settings again and repeat step 2 4 Enter the factory default username and password on the login page and clic...

Page 16: ...e range and take corresponding actions to resolve Port Status LED is Off in the Link Act Speed Mode The port is not connected or the connection is not working 1 Check if the cable connector plug is fi...

Page 17: ...o 45 Fahrenheit 4 to 158 Centigrade 20 to 70 Feet 10000 Meters 3000 Dimensions Weights Humidity Dimensions WxHxD Weight Operating Humidity Millimeters 442 x 44 x 211 Inches 17 4 x 1 73 x 8 3 Kilograms...

Page 18: ...ed to support a Layer 2 multicast domain of snooping switches in the absence of a multicast router IGMP Proxy IGMP snooping with proxy reporting or report suppression actively filters IGMP packets in...

Page 19: ...ware queues Scheduling Strict priority and weighted round robin WRR Queue assignment based on DSCP and class of service Classification Port based 802 1p VLAN priority based IPv4 IPv6 precedence DSCP b...

Page 20: ...while upgrading SNMP SNMP version1 2c and 3 with support for traps and SNMP version 3 user based security model USM Firmware Upgrade Web browser upgrade HTTP HTTPs and TFTP Upgrade through console por...

Page 21: ...00 Red Circle Drive Minnetonka MN 55343 USA Attn RETURNS DEPT CRA RMA ___________ Failure to properly protect the product during shipping may void this warranty The return authorization number must be...

Page 22: ...HER WARRANTIES SUCH AS FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSED OR IMPLIED TRANSITION NETWORKS IS NOT LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES INCLUDING LOSS...

Page 23: ...of 22 Transition Networks 10900 Red Circle Drive Minnetonka MN 55343 USA 10900 Red Circle Drive Minnetonka MN 55343 tel 1 952 941 7600 toll free 1 800 526 9267 fax 952 941 2322 Copyright 2016 Transiti...

Reviews: