SISTP10xx-141-LR(T) Industrial PoE Switch
Transition Networks
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
17
Connecting fiber cables
Fiber cable
installation
When connecting fiber cables to the 100BASE-FX port on the Industrial PoE Switch, make
sure the correct type is used: ST or SC.
To install the fiber cables, do the following:
Step
Action
1.
Remove and keep the fiber-port protective dust cover(s).
Note:
When not connected to a fiber cable, keep the protective cover(s) on the optical ports
to protect the optics and keep dust and debris from entering the optical interface.
2.
Check that the fiber connectors on the fiber-optic cabling are clean. If necessary,
clean the fiber connectors using locally accepted cleaning procedures.
Note:
Dirty fiber connectors on fiber optic cables will impair light transmission quality
through the cable and lead to degraded performance on the port.
3.
Connect the fiber cable as shown in Figure 14.
Figure 14: Fiber Cable Connections
4.
Check the corresponding fiber port LED on the Industrial PoE Switch to verify the
connection—LNK/ACT LED should be lit.
Warning
•
Visible and invisible laser radiation when open: DO NOT stare into the beam, or
directly view the beam with optical instruments. Failure to observe this warning could
result in an eye injury.
•
Use of controls, adjustments or the performance of procedures other than those
specified herein may result in hazardous radiation exposure.