Power Sensor Configuration
The Threshold Settings table lists the threshold severity, relation, and comparison value for a sensor listed in the
Entity-MIB Physical Table.
Power
: displays the most recent power measurement obtained by the agent for this sensor in Watts.
Power Status
: displays the operational power status of the sensor.
o
OK
- indicates that the agent can obtain the sensor value.
o
Unavailable
- indicates that the agent presently cannot obtain the sensor value.
o
Nonoperational
- indicates that the agent believes the sensor is broken. The sensor could have a
hard failure (disconnected wire), or a soft failure (e.g., out-of-range, jittery, or wildly fluctuating
readings).
Relay Enabled
: select
False
to disable DCR (Dry Contact Relay) operation or select
True
to enable it.
This selection enables or disables the relay contact d (ExtRelayInstalled) in the power supply.
Index
: select an index line / number that uniquely identifies an entry in the Threshold Table.
The index permits the same sensor to have several different threshold values set.
Severity
: select
Other
,
Minor
,
Major
, or
Critical
. Critical is the most severe, Major is the next most
severe, and Minor is the least severe. The system might shut down the sensor associated FRU
automatically if the sensor value reaches the Critical problem threshold.
Relation
: Less Than (<), Less Or Equal (≤), Greater Than (>), Greater Or Equal (>), Equal To (=), or
Not Equal To (≠).
o
Less Than: if the sensor value is less than the threshold value.
o
Less Or Equal: if the sensor value is less than or equal to the threshold value.
o
Greater Than: if the sensor value is greater than the threshold value.
o
Greater Or Equal: if the sensor value is greater than or equal to the threshold value.
o
Equal To: if the sensor value is equal to the threshold value.