TROUBLESHOOTING
Issue / Recommendation
Unit will not power on
-
Check for AC power at the wall outlet
-
Check output voltage of AC wall adapter; replace if faulty
-
Check the internal fuse; replace if open
-
Internal fault: Call Transcell Tech Support or installer
Display is erratic (unstable reading)
-
Check underneath the scale for any obstructions or foreign debris
-
Loose or faulty connection between the indicator and the scale platform
(homerun cable)
-
Damaged load cell (electrical overload and/or physical overload)
-
Floods can also damage load cells as well as junction boxes
-
Electromagnetic Interference (EMI). Call Transcell Tech Support or installer
-
Internal fault: Call Transcell Tech Support or installer
Transcell Tech Support:
847.419.9180
Limited 12-month Warranty
This product is warranted by TRANSCELL against manufacturing defects in material and work-
manship under normal use for twelve (12) months from the date of purchase. For complete war-
ranty details and service information, please contact us at the address below.