Neptune 6500
7
2.1
CONNECTING THE WEIGH PLATFORM TO THE INDICATOR
1.
Connect your shielded load cell cable (not included) to terminal on the main
board. Connection assignments for the Load Cell Terminal are shown in Figure
2-2.
Figure 2-2: Connection assignments for the Load Cell Terminal
Color
Wire Name
RED
+Excitation
BLK
- Excitation
GRN
+Signal
WHT
- Signal
Figure 2-2: Color Codes for Shielded Load Cell Cable
1.
If you do not wish to use the shielded load cell cable, you may use your own,
following the pin assignments shown in Figure 2-3. (A 14-pin Male Centronics-
type connector is required).
Pin Nos.
Pin Name
1/8
+Excitation
3/10
- Excitation
5/12
+Signal
7/14
- Signal
7
1
5
3
14
12
10
8
Figure 2-3: Pin assignments for the Load Cell Port