background image

16 

 

18-HD64D1-1

Feature

Description

Runtime History

The History Runtime screen provides information on system run time in comparison to the indoor 
and outdoor temperatures (average indoor along with the high & low outdoor temps).   This history 
can be viewed on a weekly or monthly basis.   

Scheduling

Allows for 7 day programming with one to six scheduled time periods per day.   
There are two options available for setting a schedule:

Guided Setup

• 

 – a step by step interactive process for setting up a schedule.  

Manual Setup

• 

 – a direct modification to an existing schedule which skips the interactive set up 

wizard from the guided set up.

Scheduling is not required.  The thermostat can operate as a non programmable thermostat.  

Screen Cleaning Mode

The Clean Screen Mode creates a 30 second screen lockout.  The screen can be touched and 
cleaned without changing settings.  There is an icon “Press and Hold to Exit” which will exit this mode 
if necessary--eliminating the 30 second lock out.

Screen Layout

The Screen Layout icon allows for customization of what is displayed on the home screen.  

SD Card Logging

The thermostat has the ability to log all information to a SD Card.   A typical 24 hour log will consist 
of 12 to 20 megabytes of information. The thermostat will overwrite the oldest data once the card 
becomes full.  

Security

Security initiates a keypad lockout.  The thermostat can only be accessed by a four digit pass code 
which can be configured in two different formats:
Pin Lock:  When the Pin Lock is selected, the thermostat is completely locked.  The user will need to 
enter a four digit password to change any setting (the default is “1234”).
Guest mode:  The enabling of this mode allows a guest to change the temperature up to 5° in either 
direction from setpoint and access to the weather, but cannot change the mode or any customized 
settings.  

Setpoint Dead Band

This sets the temperature band between heating and cooling setpoints while in the auto mode.

Software Updates

The thermostat is field software upgradable.  Insert a SD card and press the Software Update icon, 
and updates will begin automatically.  

Stage Inhibit

To prevent the next stage of capacity from being initialized, when the current capacity stage will 
satisfy the load a stage inhibit function is utilized.

System Report

The System Report Screen provides a real time in depth look at operating conditions.  While similar 
to the System Status screen, the system report adds additional information for service technicians. 

System Status

The System Status screen shows the snapshot of what the system is doing; including system mode, 
air flow percentage and reminders. 

System Test

The System Test feature allows a technician to lock the system into a particular mode of operation 
for up to 30 minutes.

Technician Access 

Screens

The “Technician Access” icon has a 5 second hold delay to enter the technician service screens.   
After this 5 second hold delay, the technician will see a “Caution!” screen noting that only a trained 
HVAC technician should proceed into this area.    

Vacation Mode

Through an interactive calendar, pick the date, time and temperature to begin and end a vacation set 
back period.

Warm Air Discharge

Enabling Warm Air Discharge will reduce the variable speed blower air flow by 20% when in com-
pressor heating operation.  Warm air discharge only applies to compressor heating and is disabled 
when hydronic, fossil fuel or electrical heat (including supplement heat) modes are activated.

Weather

The Weather feature displays the outdoor temperature, 5-day forecast and local Doppler radar.  The 
weather screen is available once Wireless Service to the internet and Remote Services are enabled.  

Summary of Contents for TZONE950AC52ZA

Page 1: ...formation is intended for use by individuals possess ing adequate backgrounds of electrical and mechanical experience Any attempt to repair a central air conditioning product may result in personal in...

Page 2: ...F resolution Heating Setpoint Temperature Range 55 F to 90 F 1 F resolution Indoor Temperature Display Range 20 F to 119 F Outdoor Temperature Display Range 31 F to 119 F Indoor Humidity Display Rang...

Page 3: ...50AC52ZA Outdoor Unit Indoor Unit Relay Panel BAY24VRPAC52DA Relay Panel Outdoor Unit Indoor Unit Communicating System 24V System Wired Remote Outdoor Sensor BAYSEN01ATEMPA Wired Remote Sensor ZZSENSA...

Page 4: ...Panel BAY24VRPAC52DA Relay Panel Outdoor Unit Indoor Unit 24V System Wired Remote Outdoor Sensor BAYSEN01ATEMPA Wired Remote Outdoor Sensor BAYSEN01ATEMPA Wired Remote Sensor ZZSENSAL0400AA Optional 2...

Page 5: ...ount the thermostat in areas where electromagnetic emissions from other devices appliances or wiring can interfere with the thermostat s communication i e wireless phones security systems wire less in...

Page 6: ...wall Do not overtighten screws to avoid damaging the sub base 1 Press tip of SnapSkru an chor into drywall using 2 Phillips screwdriver or screw gun Drive anchor clockwise into drywall until anchor st...

Page 7: ...ed cable is not typically required Keep this wiring at least one foot away from large inductive loads such as Electronic Air Cleaners motors line starters lighting bal lasts and large distribution pan...

Page 8: ...wn Blue Blue Thermostat Relay Panel Red Brown Blue B D R B D R Indoor Unit Communicating Indoor Unit Communicating Outdoor Unit Communicating System Communicating Indoor with Non Communicating Outdoor...

Page 9: ...n displays default temperature set tings and parameters Pressing a button will display additional information or a new menu screen Help Screens contain a Help button which provides additional informat...

Page 10: ...u Service Technician Access Proceed Installer Setup NOTE Press and hold the Technician Access button for 5 seconds to enter the Installer Setup screen NOTE See Section 8 for a complete list of menus a...

Page 11: ...ation Example Press the Comfort button to enable or disable comfort settings such as dehumidification at right Installer Setup Menu Advanced 11B Standard Pressing the Standard button allows manual sel...

Page 12: ...ings resets the Advanced Settings which were configured in the Installer Menu settings such as system lockouts accessories air flow and comfort options Installer Setup Menu Restore Equipment Defaults...

Page 13: ...the icon button in the top right corner of the screen will recall the alert to the home screen All alerts will remain until resolved Critical Alert indicates the loss of heating or cooling operation O...

Page 14: ...en the alert happened the severity level of the alert as well as a problem description and possible causes to assist with troubleshooting Up to the last 30 days are displayed Dual Fuel Options The cha...

Page 15: ...nt error plus integral time away from setpoint error is used to calculate load value Lockouts System lockouts will disable a certain function of the system under specific outdoor temperatures Compress...

Page 16: ...her direction from setpoint and access to the weather but cannot change the mode or any customized settings Setpoint Dead Band This sets the temperature band between heating and cooling setpoints whil...

Page 17: ...g is displayed but no warm or cool air is coming from the registers 1 There is a fan delay as the heating or cooling equipment turns on 2 Equipment is not working properly 1 Wait a minute for blower d...

Page 18: ...On Time Minutes 1 3rd Stage Indoor Heater Minimum On Time Minutes 1 Sensors Select Outdoor Temperature Sensor None Sensor Wired to Comfort Control CLII AccuLink Outdoor Sensor Sensor Wired to Relay Pa...

Page 19: ...ydronic Heat Blower On Delay No Delay 30 60 Hydronic Heat Blower Off Delay No Delay 30 60 90 Compressor Low Stage Air Flow Cooling 35 60 55 80 Compressor Low Stage Air Flow Compressor Heating 35 60 55...

Page 20: ...continuous product and product data improve ment and it reserves the right to change design and specifications without notice Representative only illustrations included in this document 6200 Troup Hi...

Reviews: