Display menu: “Data display”
From the menu screen, select “
Data
Display
” then press
Pressing or will
allow
navigation from screen 1 to 8 as
shown hereafter:
The menu is looped making it
possible to scroll from the first item
in the menu to the last item.
1. Water and air temperatures
Lvg Wat Temp =
Leaving water
temperature
Ret Wat Temp =
Entering water
temperature
Amb Temp =
Ambient air
temperature
Active StP =
Active water setpoint
2. Refrigerant pressures
HP ckt1 =
Condensing Pressure
circuit 1
HP ckt2 =
Condensing Pressure
circuit 2 (dual circuit units only)
LP ckt1 =
Evaporating Pressure
circuit 1
LP ckt2 =
Evaporating Pressure
circuit 2 (dual circuit units only)
3. Refrigerant saturated temperatures
Sat Temp CDS1 =
Condensing
temperature circuit 1
Sat Temp CDS2 =
Condensing
temperature circuit 2 (dual circuit
units only)
Sat Temp EVP1 =
Evaporating
temperature circuit 1
Sat Temp EVP2 =
Evaporating
temperature circuit 2 (dual circuit
units only)
Legend for screens 4,5 and 6:
Cmp A1 =
Compressor A/circuit 1
Cmp B1/C1 =
Compressor B and
C/circuit 1
Cmp A2 =
Compressor A/circuit 2
(dual circuit units only)
Cmp B2/C2 =
Compressor B and
C/circuit 2 (dual circuit units only)
4. Compressors status
Possible Status:
Off =
Compressor stopped
On =
Compressor running
Rec.On =
Compressor will start after
anti-short cycle
Rec.Off =
Compressor will stop after
anti-short cycle
5. Compressors running time
Hrs
indicates the number of full
hours compressor has been working
since its first start.
6. Number of compressors starts
Starts
indicates the number of
compressor starts since first start-up.
7. Operating mode
Mode =
Running mode
-
Cooling =
Cold water production
-
Heating =
Hot water production
(Reversible chillers only)
Stp Local 07.0°C
-
Stp =
Current setpoint
-
Local =
Source of Setpoint
Local =
Cooling or heating
setpoint defined locally
Extern =
Auxiliary setpoint
or operating mode by
external contact
Auto =
setpoint by the
automatic reset or the
daily/weekly program
Remote =
Setpoint by
supervisor
Ckt1/Ckt 2 =
Operational circuits
-
Enable =
Circuit is operational
-
Disable =
Circuit is not
operational
8. Compressors failures counters
This menu indicates the number of
compressors failure regardless of
the history.
Lvg Wat Temp
08.0°C
Ret Wat Temp
12.0°C
Amb Temp
28.0°C
Active StP
07.0°C
HP ckt1
00.0 bar
HP ckt2
00.0 bar
LP ckt1
00.0 bar
LP ckt2
00.0 bar
Sat Temp CDS1
00.0°C
Sat Temp CDS2
00.0°C
Sat Temp EVP1
00.0°C
Sat Temp EVP2
00.0°C
Cmp A1
Off
Cmp B1 C1
Off
Cmp A2
Off
Cmp B2 C2
Off
Cmp A1
000000 Hrs
Cmp B1 C1
000000 Hrs
Cmp A2
000000 Hrs
Cmp B2 C2
000000 Hrs
Mode
Cooling
Stp Local
07.0°C
Ckt1
Enable
Ckt2
Enable
Nb of CMP faults
Cpt
A1:0
Cpt A 2:0
Cpt
B1:0
Cpt B 2:0
Cpt
C1:0
Cpt C 2:0
Cmp A1
000000 Starts
Cmp B1 C1
000000 Starts
Cmp A2
000000 Starts
Cmp B2 C2
000000 Starts