26
LIGHT
TRIP
DASHED LINES INDICATE RECOMMENDED FIELD
AND/OR DASHED DEVICE OUTLINES INDICATE
WIRING BY OTHERS. DASHED LINE ENCLOSURES
COMPONENTS PROVIDED BY THE FIELD. PHAN TOM
LINE ENCLOSURES INDICATE ALTERNATE
SOLID LINE INDICATES FACTORY WIRING.
REMOVE JUMPER WHEN TEMPERATURE CONTROLLER
REMOVE JUMPER TO INTERFACE WITH EVF
CIRCUITRY OR AVAILABLE SALES OPTIONS.
DISCONNECT ALL ELECTRIC POWER
INCLUDING REMOTE DISCONNECTS
BEFORE SERVICING.
FAILURE TO DISCONNECT POWER
BEFORE SERVICING CAN CAUSE
SEVERE PERSONAL INJURY OR DEATH.
IMPORTANT
USE COPPER CONDUCTORS ONLY
TO PREVENT EQUIPMENT DAMAGE.
UNIT TERMINALS ARE NOT DESIGNED
TO ACCEPT ANY OTHER WIRING.
WARNING
HAZARDOUS VOLTAGE!
3
IS INSTALLED
INTERLOCK
3
2
1
NOTES:
2
2
PRESS AND HOLD SW3 BUTTON FOR 4 SECONDS TO
MEMORABLE ERRORS,THE NORMAL CODE WILL BE DISPLAYED.
ERROR/STATUS CODES.IF MORE THAN 1 ERROR HAPPENS,
THEY ARE DISPLAYED 2 SECOND EACH.IF THERE IS NOT ANY
2 SECONDS AND RETURN TO DISPLAY THE EXISTING
PRESS SW3 BUTTON FOR SHOW THE MEMORABLE ERROR.
MOMORABLE ERROR CODES THAT ARE THE CAUSES OF
EACH LOCKOUT. AFTER THAT THE 7-SEG WILL OFF FOR
THE 7-SEG WILL OFF FOR 2 SECONDS BEFORE DISPLAY THE
4
CLEAR THE MEMORABLE ERROR.
EVF INTERLOCK
TERMINATION (CONTROL)
TB
MCB
T2
T1
T3
33
32
30
N
CIRCUIT A
CIRCUIT B
COM 1
A-C2
A-C1
B-C4
B-C3
C5
COM
ALM/NO
COM 4
COM 2
COM 3
ALM/NC
COM 5
OUTPUT
THERMOSTAT STATUS
S1 - S4
44
TO TEMP. CONTROLLER STEP 1
TO TEMP. CONTROLLER STEP 2
TO TEMP. CONTROLLER STEP 4
TO TEMP. CONTROLLER STEP 3
46
45
45
41
40
40
39
LPCO 2
NORMAL
7 SEGMENT DISPLAY CODE TABLE
Error Description
OL 1 Error
OL 2 Error
OL 3 Error
OL 4 Error
HPCO 2 Error
HMWT 3 Error
HMWT 4 Error
HMWT 2 Error
HMWT 1 Error
HPCO 1 Error
LPCO 2 Error
LPCO 1 Error
- NO AC SIGNAL AT INPUTS
- CONTACT INPUTS ONLY
HMWT 4
S3
COM 0
S4
S1
S2
COM 0
H2
t3
t4
O4
O3
L2
t2
t1
O2
O1
H1
L1
WARNING :
COM 0
HMWT 3
COM 0
OL 4
HPCO 2
OL 3
COM 0
--
7 Segment Display
TYPICAL WIRING FOR RAUP 400/500
RESET 2 = RESET CIRCUIT B ON ERROR
RESET 1 = RESET CIRCUIT A ON ERROR
A CIRCUIT A-C1 ON DELAY TIME = 1 min
A CIRCUIT A-C2 ON DELAY TIME = 2 min
B CIRCUIT B-C4 ON DELAY TIME = 2.5 min
B CIRCUIT B-C3 ON DELAY TIME = 1.5 min
SYSTEM RESET : = RESET SYSTEM ON ERROR
OL 1
COMP. : START-UP TIMING
COM 0
HMWT 2
-
-
COM 0
HMWT 1
OL 2
J1
COM 0
HPCO 1
LPCO 1
INPUT
RESET 1
RESET 2
RESET 3
FAN FOR
RAUP MODEL ONLY
COMPRESSORS
B CIRCUIT
COMPRESSORS
A CIRCUIT
T2
T3
J5
N
L (240 V)
J4
C5
B-C4
B-C3
J3
A-C2
A-C1
SYSTEM RESET
STARTER CONTROLLER MODULE - I/O WIRING :-RAUP400/500
OUTPUT: USE BLACK 1 SQMM.
COI
L
COI
L
CONTROL BOX
C4
C1
INPUT: USE BLACK COLOR 0.5 SQMM.
CIRCUIT B
C3
CIRCUIT A
C2
LPCO2
HPCO2
HPCO1
LPCO1
240V/21, 8V
TX2
33
33
38
33
36
37
33
33
35
34
Termination Diagram
Schematic &
RAUP 400-500