12
SCXF-SVX01Q-EN
Digit 25— Industrial Options
A
= Protective coating evaporator coil
B
= Silver solder
C
= Stainless steel screws
D
= A and B
E
= A and C
F
= B and C
G
= A, B, and C
0
= none
Digit 26 — Drain PanType
A
= Galvanized sloped
B
= Stainless steel sloped
Digit 27 — Waterside Economizer
A
= Mechanical clean full capacity (4-row)
B
= Mechanical clean low capacity (2-row)
C
= Chemical clean full capacity (4-row)
D
= Chemical clean low capacity (2-row)
0
= None
Digit 28 — Ventilation Control
B
= Airside econ w/Traq damper, top O/A
C
= Airside econ w/ std damper, top O/A
E
= Airside econ w/Traq damper &
comparative enthalpy, top O/A
F
= Airside econ w/ std damper &
comparative enthalpy, top O/A
H
= 2-position damper ventilation interface
J
= Airside economizer interface
K
= Airside economizer interface w/
comparative enthalpy
Digit 29 — Water Piping
D
= Left hand basic piping
F
= Left hand Intermediate piping
K
= Left hand basic w/ flow switch
M
= Left hand intermediate w/ flow switch
0
= None
Digit 30 — Condenser Tube Type
A
= Standard condenser tubes
B
= 90/10 CuNi condenser tubes
0
= None (air-cooled only)
Digit 31 — Compressor Service Valves
1
= With service valves
0
= None
Digit 32— Miscellaneous System
Control
1
= Time clock
2
= Interface for remote HI (IPCB)
3
= Dirty filter switch
4
= 1 and 2
5
= 1 and 3
6
= 2 and 3
7
= 1, 2 and 3
0
= None
Digit 33 — Control Interface Options
A
= Generic BAS Module; 0-5 VDC (GBAS)
B
= Ventilation Override Module (VOM)
D
= Remote Human Interface (RHI)
G
= GBAS and VOM
H
= GBAS and RHI
J
= VOM and RHI
M
= GBAS, VOM, and RHI
N
= BACnet Communications Interface (BCI)
P
= BCI and GBAS
Q
= BCI and VOM
R
= BCI and RHI
T
= BCI and GBAS and VOM
U
= BCI and GBAS and RHI
V
= BCI and VOM and RHI
W
= BCI and GBAS and VOM and RHI
0
= None
1
= Lontalk Comm5 Interface (LCI)
2
= LCI and GBAS
3
= LCI and VOM
4
= LCI and RHI
5
= LCI and GBAS and VOM
6
= LCI and GBAS and RHI
7
= LCI and VOM and RHI
8
= LCI and GBAS and VOM and RHI
Digit 34— Agency
U
= UL agency listing
0
= None
Digit 35— Filter Type
1
= 2” T/A w/ 2” rack
2
= 2” med. eff. T/A w/ 2” rack
3
= 4” bolt-on rack w/ 2” med eff. filter
4
= 6” rack w/ 2” construction T/A pre-filter &
4” filter space
5
= 6” rack w/ 2” med. eff. T/A pre-filter & 4”
filter space
Digit 36— Miscellaneous Control
Option
A
= Low entering air temp. protect device
(LEATPD)
B
= High duct temp t-stat, ship separate
C
= Plenum high static switch, ship separate
E
= A and B
F
= A and C
H
= B and C
L
= A, B, and C
0
= None