SCXF-SVX01Q-EN
79
Pre-Startup
Before starting up units, perform the following
procedure to ensure proper unit operation.
Units with VFD
This panel is hinged to allow service access to fan
motor and belt drive components that are located
behind it.
N
No
otte
e:: The panel weight rating is 225 lbs. total including
factory-installed components.
W
WA
AR
RN
NIIN
NG
G
P
Prro
op
pe
err F
Fiie
elld
d W
Wiirriin
ng
g a
an
nd
d G
Grro
ou
un
nd
diin
ng
g
R
Re
eq
qu
uiirre
ed
d!!
F
Fa
aiillu
urre
e tto
o ffo
ollllo
ow
w cco
od
de
e cco
ou
ulld
d rre
essu
ulltt iin
n d
de
ea
atth
h o
orr
sse
erriio
ou
uss iin
njju
urry
y..
A
Allll ffiie
elld
d w
wiirriin
ng
g M
MU
US
ST
T b
be
e p
pe
errffo
orrm
me
ed
d b
by
y q
qu
ua
alliiffiie
ed
d
p
pe
errsso
on
nn
ne
ell.. IIm
mp
prro
op
pe
errlly
y iin
nsstta
alllle
ed
d a
an
nd
d g
grro
ou
un
nd
de
ed
d
ffiie
elld
d w
wiirriin
ng
g p
po
osse
ess F
FIIR
RE
E a
an
nd
d E
EL
LE
EC
CT
TR
RO
OC
CU
UT
TIIO
ON
N
h
ha
azza
arrd
dss.. T
To
o a
av
vo
oiid
d tth
he
esse
e h
ha
azza
arrd
dss,, y
yo
ou
u M
MU
US
ST
T ffo
ollllo
ow
w
rre
eq
qu
uiirre
em
me
en
nttss ffo
orr ffiie
elld
d w
wiirriin
ng
g iin
nsstta
alllla
attiio
on
n a
an
nd
d
g
grro
ou
un
nd
diin
ng
g a
ass d
de
essccrriib
be
ed
d iin
n N
NE
EC
C a
an
nd
d y
yo
ou
urr llo
occa
all//
sstta
atte
e//n
na
attiio
on
na
all e
elle
eccttrriicca
all cco
od
de
ess..
W
WA
AR
RN
NIIN
NG
G
H
Ha
azza
arrd
do
ou
uss V
Vo
olltta
ag
ge
e w
w//C
Ca
ap
pa
acciitto
orrss!!
F
Fa
aiillu
urre
e tto
o ffo
ollllo
ow
w iin
nssttrru
uccttiio
on
nss b
be
ello
ow
w cco
ou
ulld
d rre
essu
ulltt iin
n
d
de
ea
atth
h o
orr sse
erriio
ou
uss iin
njju
urry
y..
D
Diisscco
on
nn
ne
ecctt a
allll e
elle
eccttrriicc p
po
ow
we
err,, iin
nccllu
ud
diin
ng
g rre
em
mo
otte
e
d
diisscco
on
nn
ne
eccttss a
an
nd
d w
wa
aiitt ffo
orr D
DC
C cca
ap
pa
acciitto
orrss tto
o
d
diisscch
ha
arrg
ge
e b
be
effo
orre
e sse
errv
viicciin
ng
g.. R
Re
effe
err tto
o tth
he
e
m
ma
an
nu
uffa
accttu
urre
err’’ss rre
ecco
om
mm
me
en
nd
da
attiio
on
nss ffo
orr p
prro
op
pe
err
d
diisscch
ha
arrg
ge
e ttiim
me
e a
ass D
DC
C b
bu
uss cca
ap
pa
acciitto
orrss rre
etta
aiin
n
h
ha
azza
arrd
do
ou
uss v
vo
olltta
ag
ge
ess a
afftte
err iin
np
pu
utt p
po
ow
we
err h
ha
ass b
be
ee
en
n
d
diisscco
on
nn
ne
ecctte
ed
d.. F
Fo
ollllo
ow
w p
prro
op
pe
err llo
occkko
ou
utt// tta
ag
go
ou
utt
p
prro
occe
ed
du
urre
ess tto
o e
en
nssu
urre
e tth
he
e p
po
ow
we
err cca
an
nn
no
ott b
be
e
iin
na
ad
dv
ve
errtte
en
nttlly
y e
en
ne
errg
giizze
ed
d.. V
Ve
erriiffy
y w
wiitth
h a
a C
CA
AT
T IIIIII o
orr IIV
V
v
vo
ollttm
me
ette
err rra
atte
ed
d p
pe
err N
NF
FP
PA
A 7
70
0E
E tth
ha
att a
allll cca
ap
pa
acciitto
orrss
h
ha
av
ve
e d
diisscch
ha
arrg
ge
ed
d b
be
effo
orre
e tto
ou
ucch
hiin
ng
g a
an
ny
y iin
ntte
errn
na
all
cco
om
mp
po
on
ne
en
nttss..
F
Fo
orr a
ad
dd
diittiio
on
na
all iin
nffo
orrm
ma
attiio
on
n rre
eg
ga
arrd
diin
ng
g tth
he
e ssa
affe
e
d
diisscch
ha
arrg
ge
e o
off cca
ap
pa
acciitto
orrss,, sse
ee
e P
PR
RO
OD
D--S
SV
VB
B0
06
6*
*--E
EN
N..
1. Remove the unit center cover panel to the left of the
VFD panel.
2. Verify/remove/discard the sheet metal shipping
screws along the top and bottom edges of the VFD
panel.
3. Disconnect the communications cable from the
keypad on the VFD door panel.
4. Turn the two slotted-head fasteners on the right
edge of the VFD panel fully counterclockwise.
5. Pull on the handle to swing the panel 180°.
N
No
otte
e:: To secure the panel in the open position during
service procedures, attach the chain mounted to
the cabinet frame behind the unit center cover
panel to the chain retainer notch on the edge of
the VFD panel.
To close and reattach the panel, reverse the above
procedures.
N
No
otte
e:: Verify that all wires are in proper position and
not rubbing once the panel has been secured.
Pre-Startup Checklist
Complete this checklist after installing unit to verify all
recommended installation procedures are complete
before startup. This does not replace the detailed
instructions in the appropriate sections of this manual.
Always read the entire section carefully to become
familiar with the procedures.
Supply Fan
•
Verify the fan and motor shafts are parallel.
•
Verify the fan and motor sheaves are aligned.
•
Check the fan belt condition and tension. Adjust the
tension if belts are floppy or squeal continually.
Replace worn or fraying belts in matched sets.
•
Ensure the fan rotates freely.
•
Tighten locking screws, bearing set screws and
sheaves.
•
Ensure bearing locking collars do not wobble when
rotated.
•
Remove fan assembly tie down bolts.
•
Ensure fan rotation is in direction of arrow on fan
housing. If incorrect, verify incoming power
phasing is correct. Switch wires on the fan contact
to properly phase fan if necessary.
Ductwork
•
Ensure trunk ductwork to VAV boxes is complete
and secure to prevent leaks.
•
Verify that all ductwork conforms to NFPA 90A or
90B and all applicable local codes
Water-Cooled Unit Piping
•
Verify condensate drain, water piping drain plugs,
economizer header, and condenser vent plug are
installed.
Air-Cooled Units Only
•
Verify leak test was performed after refrigerant
piping was installed.
Summary of Contents for IntelliPak SCRF 25
Page 117: ...SCXF SVX01Q EN 117 N No ot te es s...
Page 118: ...118 SCXF SVX01Q EN N No ot te es s...
Page 119: ...SCXF SVX01Q EN 119 N No ot te es s...