SCXF-SVX01Q-EN
11
Model Number Description
Commercial Self-Contained Signature Series
Digit 1 — Unit Model
S
= Self-Contained
Digit 2 — Unit Type
C
= Commercial
I
= Industrial
Digit 3 — Condenser Medium
W
= Water-cooled
R
= Air-cooled
Digit 4 — Development Sequence
F
= Signature Series
Digit 5— Refrigerant Circuit
Configuration
U
= Standard Capacity
V
= High Capacity
Digit 6, 7 — Unit Nominal Capacity
20
= 20 Tons (water only)
22
= 22 Tons (water only)
25
= 25 Tons (water or air)
29
= 29 Tone (water or air)
30
= 30 Tons (air only)
32
= 32 Tons (water only)
35
= 35 Tons (water or air)
38
= 38 Tons (water only)
40
= 40 Tons (air only)
42
= 42 Tons (water only)
46
= 46 Tons (water only)
50
= 50 Tons (air only)
52
= 52 Tons (water only)
58
= 58 Tons (water only)
60
= 60 Tons (air only)
65
= 65 Tons (water only)
72
= 72 Tons (water only)
80
= 80 Tons (water only)
90
= 90 Tons (water only)
C0
= 100 Tons (water only)
C1
= 110 Tons (water only)
Digit 8 — Unit Voltage
6
= 200 volt/60 hz/3 ph
4
= 460 volt/60 hz/3 ph
5
= 575 volt/60 hz/3 ph
Digit 9 — Air Volume/Temp Control
2
= VFD and supply air temp ctrl
3
= VFD w/ bypass and supply air temp ctrl
4
= Constant volume, zone temp cool only
5
= Constant volume, w/ zone temp heat/
cool
6
= Constant volume and supply air temp ctrl
Digit 10, 11 — Design Sequence
**
= Factory Assigned
Digit 12 — Unit Construction
A
= Vertical discharge
B
= Vertical discharge with double wall
Digit 13— Flexible Horizontal
Discharge Plenum Type
B
= STD plenum w/ factory-cut holes
C
= Low plenum w/ factory-cut holes
E
= Std plenum w/ field-cut holes
F
= Low plenum w/ field-cut holes
H
= STD plenum double wall w/ field-cut
holes
J
= Low plenum double wall w/ field-cut holes
K
= Extended height plenum w/factory-cut
holes, ship separate
L
= STD plenum w/factory-cut holes, ship
separate
M
= Low plenum w/factory-cut holes, ship
separate
N
= Extended height plenum w/field-cut
holes, ship separate
P
= STD plenum w/field-cut holes, ship
separate
R
= Low plenum w/field-cut holes, ship
separate
T
= Extended height double-wall plenum w/
field-cut holes, ship separate
U
= STD double-wall plenum w/field-cut
holes, ship separate
V
= Low double-wall plenum w/field-cut
holes, ship separate
W
= STD double-wall (perf) plenum w/field-
cut holes (90 to110 ton only)
X
= Low double-wall (perf) plenum w/field-
cut holes (90 to 110 ton only)
Y
= Extended height double-wall (perf)
plenum w/field-cut holes, ship separate (90
to 110 ton only)
0
= None
Digit 14— Motor Type
2
= ODP motor
4
= TEFC motor
Digit 15, 16 — Motor HP
05
= 5 hp
07
= 7.5 hp
10
= 10 hp
15
= 15 hp
20
= 20 hp
25
= 25 hp
30
= 30 hp
40
= 40 hp
50
= 50 hp (460V, 575V only)
60
= 60 hp (90 to 110 ton only)
Digit 17, 18, 19 – Fan RPM
040
= 400 rpm
045
= 450 rpm
050
= 500 rpm
052
= 525 rpm
055
= 550 rpm
057
= 575 rpm
060
= 600 rpm
065
= 650 rpm
070
= 700 rpm
075
= 750 rpm
080
= 800 rpm
085
= 850 rpm
090
= 900 rpm
095
= 950 rpm
100
= 1000rpm
105
= 1050 rpm
110
= 1100 rpm
115
= 1150 rpm
120
= 1200 rpm
125
= 1250 rpm
130
= 1300 rpm
135
= 1350 rpm
Digit 20 — Unit Isolators
A
= Steam coil
B
= Hot water coil
C
= Electric heat, 1 stage
D
= Electric heat, 2 stage
F
= Hydronic heat ctrl interface
G
= Electric heat ctrl interface
K
= Steam coil ship separate, LH
L
= Hot water coil ship separate, LH
T
= Hot water coil, high capacity, LH
U
= Hot water coil, high capacity, LH, ship
separate
0
= None
Digit 21 — Unit Isolators
A
= Isopads
B
= Spring isolators
0
= None
Digit 22— Unit Finish
1
= Paint - Slate Gray
Digit 23— Supply Fan Options
0
= Standard fan
1
= Low CFM fan
Digit 24— Unit Connection
1
= Disconnect switch
2
= Terminal block
3
= Dual point power (2 blocks)