RT-SVX072A-EN
129
Figure 106.
Manifold pressure tap location — ultra
modulating
Tap location
for manifold
pressure
Figure 107.
Air damper location - ultra modulating
Air damper
Final Unit Checkout
After completing all of the checkout and start-up
procedures outlined in the previous sections (i.e.,
operating the unit in each of its Modes through all
available stages of cooling and heating), perform these
final checks before leaving the unit:
W
WA
AR
RN
NIIN
NG
G
H
Ha
azza
arrd
do
ou
uss V
Vo
olltta
ag
ge
e!!
F
Fa
aiillu
urre
e tto
o d
diisscco
on
nn
ne
ecctt p
po
ow
we
err b
be
effo
orre
e sse
errv
viicciin
ng
g cco
ou
ulld
d
rre
essu
ulltt iin
n d
de
ea
atth
h o
orr sse
erriio
ou
uss iin
njju
urry
y..
D
Diisscco
on
nn
ne
ecctt a
allll e
elle
eccttrriicc p
po
ow
we
err,, iin
nccllu
ud
diin
ng
g rre
em
mo
otte
e
d
diisscco
on
nn
ne
eccttss b
be
effo
orre
e sse
errv
viicciin
ng
g.. F
Fo
ollllo
ow
w p
prro
op
pe
err
llo
occkko
ou
utt//tta
ag
go
ou
utt p
prro
occe
ed
du
urre
ess tto
o e
en
nssu
urre
e tth
he
e p
po
ow
we
err
cca
an
n n
no
ott b
be
e iin
na
ad
dv
ve
errtte
en
nttlly
y e
en
ne
errg
giizze
ed
d.. V
Ve
erriiffy
y tth
ha
att n
no
o
p
po
ow
we
err iiss p
prre
esse
en
ntt w
wiitth
h a
a v
vo
ollttm
me
ette
err..
IIm
mp
po
orrtta
an
ntt:: HIGH VOLTAGE IS PRESENT AT TERMINAL
BLOCK OR UNIT DISCONNECT SWITCH.
☐
Close the disconnect switch or circuit protector
switch that provides the supply power to the unit
terminal block (2XD1 on 20-75T units / 1XD1 on 90-
130T units)or the unit mounted disconnect switch
(2QB1 on 20-75T units / 1QB1 on 90-130T units).
☐
Turn the 115 volt control circuit switch (1S1) to the
"On" position.
☐
Turn the 115 volt control circuit switch (1S20) to the
"On" position. (90-130T units only)
☐
Press the SETUP key. The LCD screen will display
various preset “parameters of operation” based on
the unit type, size, and the installed options.
Compare the factory preset information to the
specified application requirements. If adjustments
are required, follow the step-by-step instructions
provided in the appropriate programming manual
for VAV applications.
☐
Inspect the unit for misplaced tools, hardware, and
debris.
☐
Press the AUTO key to begin system operation. The
system will start automatically once the dampers
modulate and a request for either heating or
cooling has been given.
☐
Verify that all exterior panels including the control
panel doors and condenser grilles are secured in
place.