Digit 19 — Ambient Control
0
= Standard
1
= 0° Fahrenheit
Digit 20 — Agency Approval
0
= None (cULus Gas Heater, see note)
1
= cULus
Note:
Includes cULus classified gas heating
section only when second digit of
Model No. is a “F.”
Digit 21 — Miscellaneous
0
= Unit Mounted Terminal Block
A
= Unit Mounted Disconnect Switch
B
= Unit Mounted Disconnect Switch with
High Fault SCCR
D
= Unit Mounted Disconnect Switch with
Convenience Outlet
E
= Unit Mounted Disconnect Switch with
High Fault SCCR and Convenience Outlet
Digit 22 — Refrigeration Options
0
= Without Hot Gas Bypass
B
= Hot Gas Bypass
Digit 23 — Economizer Control
Options
C
= Economizer Control with Comparative
Enthalpy
D
= Economizer with Differential Dry Bulb
Z
= Economizer Control with Reference
Enthalpy
W
= Economizer Control with Dry Bulb
Digit 24 — Damper Options
0
= Standard Dampers
E
= Low Leak Economizer Dampers
U
= Ultra Low Leak Economizer Dampers and
Ultra Low Leak motorized relief dampers
Digit 25 — Power Meter
0
= None
1
= Power Meter
Digit 26 — Efficiency Options
0
= Standard Efficiency Unit
H
= High Efficiency Unit
Digit 27 — Condenser Coil Options
0
= Air Cooled Aluminum Condenser Coil
J
= Corrosion-Protected Condenser Coil
Digit 28 — Rapid Restart
0
= Non-Rapid Restart
R
= Rapid Restart
Digit 29 — Miscellaneous
0
= Motors without Internal Shaft Grounding
A
= Motors with Internal Shaft Grounding
Digit 30 — Expansion Module
0
= None
E
= Expansion Module
Digit 31 — Miscellaneous
N
= Ventilation Override Module
Digit 32 — Service Options
0
= None
R
= Extended Grease Lines
3
= Stainless Steel Sloped Drain Pan
4
= Stainless Steel Sloped Drain Pan with
Grease Lines
Digit 33 — Cabinet Options
0
= Standard Panels
1
= Standard Panels with Double Wall
T
= Hinged Access Doors
2
= Hinged Access Doors with Double Wall
U
= IRU - with Standard Panels
3
= IRU - with Standard Panels with Double
Wall
W
= IRU - with Hinged Access Doors
4
= IRU - with Hinged Access Doors with
Double Wall
Y
= IRU with SST - with Standard Panels
5
= IRU with SST - with Standard Panels with
Double Wall
Z
= IRU with SST - with Hinged Access Doors
6
= IRU with SST - with Hinged Access Doors
with Double Wall
Digit 34 — Filter Monitor
0
= None
1
= Pre-Evaporator
2
= Pre-Evaporator and Final Filter
Digit 35 — BAS/Communication
Options
0
= None
7
= Trane LonTalk Communication Interface
Module
8
= ModBus
®
M
= BACnet
®
Communication Interface (BCI)
Module
W
= Air-Fi
®
Wireless
Digit 36 — Isolators
8
= Spring Isolators
Digit 37 —Airflow
A
= Downflow Supply/Upflow Return
B
= Horizontal Right Supply/ Horizontal End
Return
C
= Horizontal Right Supply/Upflow Return
E
= Downflow Supply/Horizontal End Return