WSHP-SVX014F-EN
37
W
WA
AR
RN
NIIN
NG
G
P
Prro
op
pe
err F
Fiie
elld
d W
Wiirriin
ng
g a
an
nd
d G
Grro
ou
un
nd
diin
ng
g
R
Re
eq
qu
uiirre
ed
d!!
F
Fa
aiillu
urre
e tto
o ffo
ollllo
ow
w cco
od
de
e cco
ou
ulld
d rre
essu
ulltt iin
n d
de
ea
atth
h o
orr
sse
erriio
ou
uss iin
njju
urry
y..
A
Allll ffiie
elld
d w
wiirriin
ng
g M
MU
US
ST
T b
be
e p
pe
errffo
orrm
me
ed
d b
by
y q
qu
ua
alliiffiie
ed
d
p
pe
errsso
on
nn
ne
ell.. IIm
mp
prro
op
pe
errlly
y iin
nsstta
alllle
ed
d a
an
nd
d g
grro
ou
un
nd
de
ed
d
ffiie
elld
d w
wiirriin
ng
g p
po
osse
ess F
FIIR
RE
E a
an
nd
d E
EL
LE
EC
CT
TR
RO
OC
CU
UT
TIIO
ON
N
h
ha
azza
arrd
dss.. T
To
o a
av
vo
oiid
d tth
he
esse
e h
ha
azza
arrd
dss,, y
yo
ou
u M
MU
US
ST
T ffo
ollllo
ow
w
rre
eq
qu
uiirre
em
me
en
nttss ffo
orr ffiie
elld
d w
wiirriin
ng
g iin
nsstta
alllla
attiio
on
n a
an
nd
d
g
grro
ou
un
nd
diin
ng
g a
ass d
de
essccrriib
be
ed
d iin
n N
NE
EC
C a
an
nd
d y
yo
ou
urr llo
occa
all//
sstta
atte
e//n
na
attiio
on
na
all e
elle
eccttrriicca
all cco
od
de
ess..
External Smoke Detection
Wiring to Unit
Deluxe Controller
To inhibit operation of the compressor and fan for a
safety shutdown, it is necessary to break the wire (21X)
from the 24Volt transformer to the 1TB1 terminal block.
This can be done with the dry contacts of a relay. When
that connection is opened, it terminates voltage to both
the deluxe controller and the thermostat, which stops/
prevents all control function to the fan and compressor.
UC400B Controller
To inhibit operation of the compressor and fan for a
safety shutdown, it is necessary to break the wire (21A)
from the 24Volt transformer to the UC400B (1U1). This
can be done with the dry contacts of a relay. When that
connection is opened, it terminates the power voltage
to the controller, which stops/prevents all control
function including the fan and compressor.
ZN524 Controller
To inhibit operation of the compressor and fan for a
safety shutdown, it is necessary to break the wire (21X)
from the 24Volt transformer to the 1TB1 terminal block.
This can be done with the dry contacts of a relay. When
that connection is opened, it terminates the power
voltage to the controller which stops/prevents all
control function including the fan and compressor.
Hole Plug Installation
1. Locate two Hayco plastic plugs enclosed with the
Installation, Operation and Maintenance manual.
2. Use these plugs to plug the two shipping bolt holes
in the bottom of the units after shipping bolt
removal.
Airflow Adjustment
W
WA
AR
RN
NIIN
NG
G
R
Ro
otta
attiin
ng
g C
Co
om
mp
po
on
ne
en
nttss!!
F
Fa
aiillu
urre
e tto
o d
diisscco
on
nn
ne
ecctt p
po
ow
we
err b
be
effo
orre
e sse
errv
viicciin
ng
g cco
ou
ulld
d
rre
essu
ulltt iin
n rro
otta
attiin
ng
g cco
om
mp
po
on
ne
en
nttss ccu
uttttiin
ng
g a
an
nd
d sslla
assh
hiin
ng
g
tte
ecch
hn
niicciia
an
n w
wh
hiicch
h cco
ou
ulld
d rre
essu
ulltt iin
n d
de
ea
atth
h o
orr sse
erriio
ou
uss
iin
njju
urry
y..
D
Du
urriin
ng
g iin
nsstta
alllla
attiio
on
n,, tte
essttiin
ng
g,, sse
errv
viicciin
ng
g a
an
nd
d
ttrro
ou
ub
blle
essh
ho
oo
ottiin
ng
g o
off tth
hiiss p
prro
od
du
ucctt iitt m
ma
ay
y b
be
e
n
ne
ecce
essssa
arry
y tto
o w
wo
orrkk w
wiitth
h lliiv
ve
e a
an
nd
d e
ex
xp
po
osse
ed
d rro
otta
attiin
ng
g
cco
om
mp
po
on
ne
en
nttss.. H
Ha
av
ve
e a
a q
qu
ua
alliiffiie
ed
d o
orr lliicce
en
nsse
ed
d sse
errv
viicce
e
iin
nd
diiv
viid
du
ua
all w
wh
ho
o h
ha
ass b
be
ee
en
n p
prro
op
pe
errlly
y ttrra
aiin
ne
ed
d iin
n
h
ha
an
nd
dlliin
ng
g e
ex
xp
po
osse
ed
d rro
otta
attiin
ng
g cco
om
mp
po
on
ne
en
nttss,, p
pe
errffo
orrm
m
tth
he
esse
e tta
asskkss..
Horizontal - Units with Deluxe 24V or
Tracer® ZN524 controls
For horizontal sizes EXHF 006-070 and DXHF 024-070,
the ECM is programmed for constant CFM over a range
of static pressures. The DIP switch on the ECM control
board allows for a quick fan speed adjustment to
optimize unit performance. The factory default setting
is Profile B.
Figure 29.
ECM control board
To adjust the cfm, set the DIP switch located in the
control box to the desired profile setting.
Profile A = 110% of rated airflow
Profile B = 100% of rated airflow
Profile C = 90% of rated airflow
Profile D = 80% of rated airflow
Horizontal - Units with Deluxe 24V,
Tracer® ZN524 or Tracer® UC400
controls
Installations at higher altitudes may require an
adjustment to the fan speed setting to achieve proper
airflow. A second control board located in the control
box is provided with DIP switches to allow a quick
adjustment. Using the chart below, select the DIP
switch setting based on the job site’s altitude. If a lower