3
1. SAFETY WARNING
1.
Before using the machine it is essential for the safe and correct operation of the equipment that this manual be
read and fully understood and that all the instructions be followed. This manual should be made available to
every operator. Extra copies of this manual will be supplied on request.
2.
The supertirfor™ is designed for operations requiring a high degree of safety. Persons using this hoist must be
qualified for the safety requirements involved in operations using this tool. The hoist must only be operated by
single operator.
3.
Never use a machine which is not in good working condition. Replace any worn or damaged wire rope. Continuous
monitoring of the condition of the machine, its wire rope and anchor sling is an important safety consideration.
4.
TRACTEL
®
declines any responsibility for accidents or damage resulting from disassembly of the unit or any
unauthorized changes made to the hoist or its cable, in particular, when replacing parts or a cable obtained from
another supplier.
5.
The hoists described in this manual can only be used for pulling and lifting operations.
They should never be
used for lifting persons.
6.
Never attempt to overload the machine.
7.
The hoists described in this manual can never be used in an explosive environment.
8.
Do not use the holes in the compressed air cylinder mounting clevis to secure the unit.
9.
Never use a direct supply for the hoists; only the control console should be used.
10. IMPORTANT:
If the equipment described in this manual is supplied to an employed person, check that you meet
your obligations with respect to safety at work regulations.
SPECIAL APPLICATIONS
For all special applications, do not hesitate to contact the TRACTEL
®
company.
2. SPECIFICATIONS
MODEL
TU16A
TU32A
Load
1 600 kg
3 200 kg
TRACTEL
®
original cable
Ø 11.5 mm
Ø 16.3 mm
Breaking load, original cable
9 600 kg
19 200 kg
Cable weight per meter
0.50 kg
1.06 kg
Weight in working order
40 kg
88 kg
Dimensions 16A
970 x 220 x h 400 mm
940 x 400 x h 610 mm
Maximum operating pressure
7 atm
7 atm
Working pressure
6 atm
6 atm
Average consumption
550 lt/min
700 lt/min
Piston stroke
130 mm
200 mm
Self-reversing cylinder
Ø 100 mm
Ø 125 mm
Operating temperature in dry air
-10°C/+50°C
-10°C/+50°C
Sound level in operation
< 70 dbA
< 70 dbA
GB
GB
DE
NL