10
GB
5. Using the load limiter HF 31/1/A2
Periodically check correct operation of the load
limiter and the accuracy of the threshold settings in
accordancewiththeapplicationregulations.
6. Marking
1
Identification
2
Deviceserialnumber
3
Symbolindicating«Youmustreadtheusermanual»
4
Compatiblewireropediameters
5
Capacityonstrand
6
Protectionindex
7
Microswitchinterruptingcapacityandvoltage
8
Adjustmentscrewandlocknutforthreshold2
9
Adjustmentscrewandlocknutforthreshold1
10 Option:factorysettingparametersforthreshold1
11 Option:factorysettingparametersforthreshold2
7. Maintenance
No special maintenance is required for this type of
device. When performing periodic inspection, check
that the connecting cable to the control circuit is
properlysecuredandisingoodcondition.
8. Prohibited use
Do not:
– Usetheloadlimiterwithoutfirstbecomingfamiliar
withtheusermanual.
– Use the load limiter outside the validity periods
definedbytheperiodicinspectionplantowhich
thedeviceissubject.
– Usetheloadlimiterifitsconnectionorcondition
areinvisiblypoorcondition.
– Shunt the electrical circuit controlled by the
device.
9. Declaration of conformity
Seeendofmanual