MENU SYSTEM
Page
52
Copyright
Trace Engineering Company, Inc.
5916 - 195th Street N. E.
Arlington, WA 98223
Telephone: 360/435-8826
Fax: 360/435-2229
www.traceengineering.com
SW Series Inverter/Charger
Part No. 2031-5
Rev. B: Sept 1, 1999
Set Relay 9
volts DC
14.5
Set Relay 9
volts DC
29.0
Set Relay 9
volts DC
58.0
12 VDC Models
Range: 05.0 to 17.6
24 VDC Models
Range: 10.0 to 35.5
48 VDC Models
Range: 20.0 to 71.0
Sets the voltage trip point for the auxiliary relay number 9. This setting is compensated for the battery
temperature when using the BTS. There is no intentional time delay on the reaction for this setting. This
allows fast response to rapid voltage changes in the system.
R9 Hysteresis
volts DC
01.0
R9 Hysteresis
volts DC
02.0
R9 Hysteresis
volts DC
04.0
12 VDC Models
Range: 00.1 to 12.8
24 VDC Models
Range: 00.1 to 12.8
48 VDC Models
Range: 00.2 to 25.6
The hysteresis setting for relay number 9. There is an intentional 2-second time delay to reduce cycling.
Set Relay 10
volts DC
14.8
Set Relay 10
volts DC
29.5
Set Relay 10
volts DC
59.0
12 VDC Models
Range: 05.0 to 17.6
24 VDC Models
Range: 10.0 to 35.5
48 VDC Models
Range: 20.0 to 71.0
Sets the voltage trip point for the auxiliary relay number 10. This setting is compensated for the battery
temperature when using the BTS. There is no intentional time delay on the reaction for this setting. This
allows fast response to rapid voltage changes in the system.
R10 Hysteresis
volts DC
01.0
R10 Hysteresis
volts DC
02.0
R10 Hysteresis
volts DC
04.0
12 VDC Models
Range: 00.1 to 12.8
24 VDC Models
Range: 00.1 to 12.8
48 VDC Models
Range: 00.2 to 25.6
The hysteresis setting for relay number 10. There is an intentional 2-second time delay to reduce cycling.
Set Relay 11
volts DC
15.0
Set Relay 11
volts DC
30.0
Set Relay 11
volts DC
60.0
12 VDC Models
Range: 05.0 to 17.6
24 VDC Models
Range: 10.0 to 35.5
48 VDC Models
Range: 20.0 to 71.0
Sets the voltage trip point for the auxiliary relay number 11. This setting is compensated for the battery
temperature when using the BTS. There is no intentional time delay on the reaction for this setting. This
allows fast response to rapid voltage changes in the system.
R11 Hysteresis
volts DC
01.0
R11 Hysteresis
volts DC
02.0
R11 Hysteresis
volts DC
04.0
12 VDC Models
Range: 00.1 to 12.8
24 VDC Models
Range: 00.1 to 12.8
48 VDC Models
Range: 00.2 to 25.6
The hysteresis setting for relay number 11. There is an intentional 2-second time delay to reduce cycling.
INFORMATION DISPLAY
The following information is displayed as additional Menu Items.
Close on batt > setpoint. Open on batt < setpoint – hys.
Relays have 2 seconds delay on close, 0.1 sec delay on open.
Summary of Contents for SW II - REV 4.01
Page 151: ......