SETUP MENU MAP
The SETUP MENU provides all the controls and settings needed when installing or adjusting the
system. To access the SETUP MENU, press both the red ON/OFF MENU and green GEN MENU buttons
on the Control Panel at the same time. To exit the SETUP MENU, press the red ON/OFF MENU button or
press the down MENU HEADING button until you reach the USER MENU (menu headings 1-8).
Inverter Setup
9
Battery Charging
10
AC Inputs
11
Gen Auto Start
setup
12
Gen starting
details
13
Auxiliary Relays
R9 R10 R11
14
Set Grid Usage
FLT SELL SLT LBX
Set Bulk
volts DC
14.4
Set Grid (AC1)
amps AC
60
Set Load Start
amp AC
20
Set RY7 Function
GlowStop Run
Set Relay 9
volts DC
14.5
Set Low battery
cut out VDC
11.0
Set Absorption
time h:m
02:00
Set Gen (AC2)
amps AC
30
Set Load Start
delay min
5.0
Set Gen warmup
seconds
60
R9 Hysteresis
volts DC
01.0
Set LBCO delay
minutes
10
Set Float
volts DC
13.4
Set Input lower
limit VAC
108
Set Load Stop
delay min
5.0
Set Pre Crank
seconds
10
Set Relay 10
volts DC
14.8
Set Low battery
cut in VDC
13.0
Set Equalize
volts DC
14.4
Set Input upper
limit VAC
132
Set 24 hr start
volts DC
12.3
Set Max Cranking
seconds
10
R10 Hysteresis
volts DC
01.0
Set High battery
cut out VDC
16.0
Set Equalize
time h:m
02:00
Set 2 hr start
volts DC
11.8
Set Post Crank
seconds
30
Set Relay 11
volts DC
15.0
Set search
watts
48
Set Max Charge
amps AC
20
Set 15 min start
volts DC
11.3
R11 Hysteresis
volts DC
01.0
Set search
spacing
59
Set Temp Comp
LeadAcid
NiCad
Read LBCO 30 sec
start VDC
11.0
Close on batt >
setpoint.
Set Exercise
period days
30
Open on batt <
setpoint - Hys
Set Maximum run
time h:m
08:00
Relays have 2
second delay on
Set Max Run time
to 0 to defeat.
Close, 0.1 sec
delay on open
Set Exercise to 0
to defeat.
See menu 9 to
to set LBCO.
Bulk Charge
Trigger Timer
15
Low Battery
Transfer (LBX) 16
Battery Selling
17
Grid Usage Timer
18
Information file
battery
19
End Setup Menu
20
Set Start Bulk
time
00:00
Set Low Battery
TransferVDC
11.3
Set Battery Sell
volts DC
13.4
Start Charge
time
21:00
Batt temp comp
changes battery
To disable timer
set to 00:00
Set Low battery
cut in VDC
13.0
Set Max Sell
amps AC
30
End Charge
time
21:00
voltage reading
away from actual
If grid timer
active set bulk
See menu 9 to
enable LBX mode.
See menu 9 to
enable SELL mode.
After Start
Charge time:
HBCO resets at:
6v/48, 3v/24 and
time after start
charge time.
Make sure LBX is
above LBCO volts.
Make sure LBX is
above LBCO volts.
SELL mode
charges battery.
1.5v/12v under
HBCO.
In SLT mode don’t
disable this
FLT mode
charges battery
LowBattTransfer
used in LBX, FLT
timer. It is the
daily chg time.
After End Charge
time:
Modes only. Goes
back to battery
SELL mode sells
battery to AC1.
at LowBattCutIn
(aka LBCI).
FLT mode drops
AC1 and inverts
For LBX mode set
below LBCI so
Timer on when
start < > end;
charger won’t
cycle batteries
timer off when
start = end
up and down and
set LBCO below.
Sell and float
modes use timer
SLT and LBX mode
ignore timer
MENU HEADINGS
MENU ITEMS