4.4 Shield cover
The shield cover is connected with a special EMC cable gland, whereby the cable
shielding is fitted on the inside.
Cable gland assembly, variant A
Pos. 1 Nut
Pos. 2 Seal
Pos. 3 Contact bush
Pos. 5 Screw socket
1. Cut shield braid / shield foil back to
dimension "X"
.
2. Slide the nut (1) and seal / contact bush (2) + (3) over the cable.
3. Bend the shield braining / shield foil to 90° (4).
4. Slide seal / contact bush (2) + (3) up to the shield braining / shield foil.
5. Assemble screw socket (5) on the housing.
6. Push seal / contact bush (2) + (3) flush into the screw socket (5).
7. Screw the nut (1) to the screw socket (5).