![TR-Electronic CEV-115 User Manual Download Page 104](http://html1.mh-extra.com/html/tr-electronic/cev-115/cev-115_user-manual_1146699104.webp)
Parameterization and configuration
TR-Electronic GmbH 2013, All Rights Reserved
Printed in the Federal Republic of Germany
Page 104 of 136
TR - ECE - BA - DGB - 0104 - 07
11/07/2018
Operating parameter Teach-In function
Description see page 114
DDLM_Set_Prm
unsigned8
Byte
10
Bit
7
6
5
4
3
2
1
0
Data
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
Disabled no status
(Default)
0
0
0
0
0
0
0
0
Disabled with status
0
0
0
0
0
0
1
0
Enabled with status
0
0
0
0
0
0
1
1
Associated operating parameters for scaling with gearbox function
Description see page 119
DDLM_Set_Prm
unsigned32
Byte
11
12
13
14
Bit
31 – 24
23 – 16
15 – 8
7 – 0
Data
2
31
– 2
24
2
23
– 2
16
2
15
– 2
8
2
7
– 2
0
Default (dec.)
16777216
Total measuring range
DDLM_Set_Prm
unsigned32
Byte
15
16
17
18
Bit
31 – 24
23 – 16
15 – 8
7 – 0
Data
2
31
– 2
24
2
23
– 2
16
2
15
– 2
8
2
7
– 2
0
Default (dec.)
4096
Revolutions numerator
DDLM_Set_Prm
unsigned16
Byte
19
20
Bit
15 – 8
7 – 0
Data
2
15
– 2
8
2
7
– 2
0
Default (dec.)
1
Revolutions denominator