29
9. Notepad Function
9.1 Recording Readings into the Notepad
To record readings into the Notepad memory…
1.
Press
in normal display mode. The display should now look like this:
10.0ppM 7.00pH 500.0mV 25.0
10.0ppM 7.00pH 500.0mV 25.0
O
O
c
c
Log# 1, Press F1 31/12/98 12:00:00
Log# 1, Press F1 31/12/98 12:00:00
2.
Press
, to record all three Channels of Ion/pH/mV data, plus Temperature, Date and Time
into the notepad. This will be labeled as reading number 1.
Alternatively, press
to quit without recording the reading.
3.
Repeat steps 1 & 2 as often as required. The maximum number of readings that can be stored in
the Notepad is 1200.
9.2 Recalling Readings from the Notepad
To recall records from the Notepad onto the
900-I3
display…
1.
Select the Notepad menu (
→
→
F2:Notepad
F2:Notepad
)
2.
Select
F1:Recall
F1:Recall
from the menu.
Record number 1 is now displayed.
For example…
10.0ppM 7.00pH 500.0mV 25.0
10.0ppM 7.00pH 500.0mV 25.0
O
O
c
c
Log# 1, F2:
Log# 1, F2:
↑↑
F4:
F4:
↓↓
31/12/98 12:00:00
31/12/98 12:00:00
3.
Press
to display the next record.
Press
to display the previous record.
Press and hold
or
to roll rapidly through the readings.
To display a specific record, type in the desired record number using the Numeric Keypad and
press
.
Press
to send the displayed record to the optional RS232 port.