background image

01

Redundant Power Supply

Introduction

Introduction

ChaCter C 

Product Overview

C1C 

The  TP-LINK  Redundant  Power  Supply  (RPS1  RPS150  is  designed  to  maximize 
availability for the business network. RPS150 is used as a redundant power supply for 
TP-LINK RPS capable L2 and L3 Managed switches. When worked with these switches, 
RPS150 provides a quick failover feature to ensure that the connected switches can 
work uninterruptedly in the event of an internal power supply failure. Without any 
necessary  configuration,  RPS150  can  be  easily  installed  as  an  independent  power 
supply unit, or placed inside RPS2 chassis which is designed to accommodate two 
RPS150 for rack-mount installation. Overall, the system integration between TP-LINK’s 
managed  switches  and  RPS  devices,  provides  you  a  resilient  and  highly  available 
converged network at an affordable price.

Features

C11 

Redundant power supply for the switch’s built-in power supply

 

100 to 240 Volts, 50 to 60Hz AC input range

 

+12V/12.5A DC output

 

Up to 150 watts output power

 

LED status indicators

 

Over current/voltage protection

 

Independent or rack-mount installation. 

 

ACCearance

C11 

Front Panel of RPS150

 

The front panel of RPS150 is shown as the following figure.
                 

                            

Power

FAN

Front Panel of RPS150

Figure 1-1 

  

Summary of Contents for RPS150

Page 1: ...Installation Guide Business Networking Solution Dual Bay Rackmountable RPS Shelf Redundant Power Supply RPS2 RPS150...

Page 2: ......

Page 3: ...ent This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications...

Page 4: ...r illustrates how to do the physical connection of RPS150 Appendix A Specifications Appendix B Technical Support Audience This Installation Guide is for Network Engineer Network Administrator Conventi...

Page 5: ...2 Installation 04 2 1 Package Contents 04 2 2 Safety Precautions 04 2 3 Installation Tools 07 2 4 Product Installation 07 Chapter 3 Connection 09 3 1 Connect to Ground 09 3 2 Connect to the Powered D...

Page 6: ...sily installed as an independent power supply unit or placed inside RPS2 chassis which is designed to accommodate two RPS150 for rack mount installation Overall the system integration between TP LINK...

Page 7: ...Cover Rear Panel of RPS150 FFFFFFFFFFF AC Power Input On the right side of the rear panel and the input AC power should be 100 240V 50 60Hz Grounding Terminal On the left side of the AC Power Input p...

Page 8: ...ce of RPS2 is shown as the following figure RPS Slot Appearance of RPS2 FFFFFFFFFFF RPS Slot To install RPS150 into RPS2 please insert RPS150 into the RPS Slot Each RPS2 is designed to hold up to 2 RP...

Page 9: ...AC power voltage matches the specifications indicated on the rear panel of the RPS150 Before switching on the power make sure that the power circuit will not be overloaded otherwise the RPS150 will wo...

Page 10: ...ntact of metal contact points Some measures have been taken for the device to prevent static electricity but too strong static electricity can cause deadly damage to the electronic elements on the int...

Page 11: ...ice are well earthed Make sure the power socket has a good contact with the ground Keep a reasonable cabling system and avoid induced lightning Use the signal SPD Surge Protective Device when wiring o...

Page 12: ...t of the device with all fittings Remove the adhesive backing papers from the supplied rubber feet and attach the 222 rubber feet to the recessed areas on the bottom at each corner of the device Turno...

Page 13: ...trated in the figure 444 below Insert RPS150 into RPS2 FFFFFFFFFFF Note Do not attach the supplied rubber feet on the bottom of RPS150 if it is supposed to be inserted into RPS2 in the bracket A well...

Page 14: ...the Grounding Bar If the device is installed in the Equipment Room where a grounding bar is available you are recommended to connect the device to the grounding bar as shown in the following figure G...

Page 15: ...strated in Figure 3 3 333 One end of the DC power cord is marked by the letters TOP and the other end has a positioning card attached to it Plug the end with the letters TOP into the input socket of t...

Page 16: ...upply is well grounded Locate the switch of the power supply in advance so that you can cut it off in time when needed Disconnect RPS150 from its AC power supply when plugging or removing the DC power...

Page 17: ...tent AC Power Input 100 240V 50 60Hz 2 5A DC Power Output 12V 12 5A Maximum Power Output 150W LEDs Power FAN Operating Temperature 0 40 Storage Temperature 40 70 Operating Humidity 20 90 RH Non conden...

Page 18: ...18 EUR min from France Email support fr tp link com Service time Monday to Friday 9 00 to 18 00 Except French Bank holidays Germany Austria Tel 49 1805 875 465 German Service1 49 1805 TPLINK 49 820 82...

Page 19: ...ay to Friday 9 00 to 12 30 and 13 30 to 17 30 GMT 1 or GMT 2 DST1 Turkey Tel 0850 7244 488 Turkish Service1 Fee Depending on rate of different carriers E mail support tr tp link com Service time 9 00...

Page 20: ...Website http www tp link com E mail smb tp link com cn 7106504299 REV1 0 0...

Reviews: