73
Start
Time
Mode
Setting
Power
supply on
Power
turned on
Failure
Power indicator is lit
MODE
SELECT
Heating
Cooling
Drying
Stop in
Emergency
Self-detecting
Stop
Protection
Under
operation
Anti-stop indicator is lit
Time Setting
(Use buttons up & down)
Set time - past time = 0
Stop
Anti-stop indicator is lit
Time Setting
(Use buttons up & down)
Set time - past time = 0
NO
Yes
<Note 1>
Yes
NO
<Note 2>
Yes
<Note 3>
NO
NO
NO
Yes
Yes
Dry
Heat
Cool
<Note 4>
<Note 5>
Yes
NO
Yes
No
●附录:
一、制冷剂补充量
1
、对于
KF(R)-40
~
60LW(/D)
:如果制冷剂管道长度>
7m
,每增加
1m
补充制冷剂
50g
;
2
、对于
KF(R)-70
~
120LW(/D)
,如果制冷剂管道长度>
7m
,每增加
1m
补充制冷剂
80g
。
因制冷剂管道长度超过
15m
,则严重影响空调器的制冷效果,所以制冷剂管道不宜超过
15m
。
Pipeline exhaust and leakage hunting
1
、
Exhaust air
If there is moist air in system, it will lead to an abnormal working of the compressor, so when fixing, the air
inside connect pipe should be exhaust out, you have three way to let out the air:
First way: let out the air with its own refrigerant of the unit.
Connect the indoor unit and outdoor unit with connect pipe, tighten the nut, open the gas valve screw cap, liquid
valve screw cap, freon charge screw cap, open the liquid valve (rotate 1/4 circle) 0
—
10 seconds, meanwhile, using
the inner six angle spanner to make the freon charge thimble up to outlet the air in the gate of the valve. Stop when
your hand feel cold, and the quantity of the exhausted freon should less than 20g.
Second way: using vacuum pump.
Connect the indoor unit and outdoor unit with connect pipe, tighten the nut,
将多用表的歧管阀充注软管连接