45
一
一
一
一
. 40LW control function
1. Function control
1)
Cooling heating dehumidifying auto modes to choose.
2) On-timer
function
3)
Auto defrosting function
4)
Set temperature range: 18 - 30
℃
5)
Compressor restart 3 minutes delay protection
6)
Auto flow, high flow, middle flow, low flow to choose.
7) Self diagnosis function.
2. Controller description
There are 3 parts controller, including remote control, indoor operation panel, indoor control
main board.
3. Controlled object
:
1) Indoor fan motor
(
Fan motor, Hi
、
Mid
、
Lo
)
;
2) Air flow direction (
同步
motor)
3) Compressor
4) Outdoor
fan
motor
5) Reversing
valve
4. Data
1) Room temperature = Ta
2) Evaporate temperature = Te
3) Condenser temperature = Tc
5. Description of the operation panel:
Power
Air flow direction
Air speed
Indicator light
:
Power indicator
(
Green and Red
)
、
On-Timer indicator
(
yellow
)
Button
:
On/off
、
Air direction
、
Air speed
5.1 Button description
:
:
:
:
1) On/off
:
:
:
:
a
.
Press one time
,
the unit is on, press again, the unit is off. At the beginning the unit goes into Auto mode,
On/off
On/off
Air Direction
Air
Speed
On
Timer