15. Guarantee                  

       

                                                                                     

 

   

 

     

(1) Guarantee period 

       

  One (1) year after delivery to the specified place. 

 

     

(2) Scope of guarantee 

If the equipment is found to have a fault attributable to us during the guarantee period specified 
above, the faulty part will be replaced or repaired on our risk. This does not apply to: 

 

         

1) the faults resulting from the incorrect handling or misuse by the user 

         

2) those resulting from a cause not related with the equipment 

         

3) those resulting from the modification or repair by parties other than us, and 

         

4) those resulting from a natural disaster or accident beyond our control. 

 

For the purpose of this document, the guarantee applies to the equipment itself and does not apply 
to the secondary damage caused by the malfunction of the equipment. 

 
 

   

16. For Contact

                                                                       

 

 

For further information about the product, please contact our sales office nearby or the Machinery 
Division, Kamiya Factory. 

 
 

         

TOYO ELECTRIC CORP., Electric Machinery Div. 

 

       

Head Office

   

  Hikisawa 1-39, Kamiya-cho, Kasugai, Aichi, Japan 480-0393 

       

/Kamiya Plant 

TEL <0568> 88-1181    FAX <0568> 88-3086 

       

Tokyo Office 

(Uchikanda 282 Blg, No. 95) 15-9, Uchikanda 2-chome, Chiyoda-ku, Tokyo   
101-0047 

                   

 

TEL <03> 3256-6665    FAX <03> 3254-3650 

       

Kanagawa Office (City Mason, No. 203) Miyata-cho 1-4-17, Hodogaya-ku, Yokohama City, 

Kanagawa  240-0002 

                     

  TEL <045> 340-1766    FAX <045> 340-1767 

       

Nagoya Office

 

  156, Ajimi-cho 2-chome, Kasugai City, Aichi    450-0002 

                     

  TEL <0568> 35-3456    FAX <0568> 34-4666 

       

Toyota Office      1-15-8, Kosaka-honmachi, Toyota City, Aichi    471-0034 

                     

  TEL <0565> 37-8830    FAX <0565> 37-8832 

       

Osaka Office

   

(Osaka Godo Blg, No. 805) 1-5, Doyama-cho, Kita-ku, Osaka City    530-0027 

                     

  TEL <06> 6361-1626    FAX <06> 6312-6762 

       

Nishi-Nihon Office

 

(Abundant 90, No. 301) Hakata Eki Higashi 3-11-4, Hakata-ku, Fukuoka City, 

Fukuoka  812-0013 

                       

TEL <092> 413-2300    FAX <092> 413-2312 

 

                 

Website: URL   

http://www.toyo-elec.co.jp

 

 

*   Specifications, dimensions, etc. shown in this operation manual may be changed to reflect the 

performance improvement without notice. 

 

Summary of Contents for SOT-EQ80 Series

Page 1: ...DS4 2499D 1 Optical Transmitter SOT EQ80 Series Operation Manual TOYO ELECTRIC CORP...

Page 2: ...tions of Components 5 6 Installation 6 7 Electric Connections and Wiring 8 8 Setting Switches 10 9 Adjustment of the Optical Axis 11 10 Operation 12 11 Signal Interface 14 12 Maintenance and Inspectio...

Page 3: ...requency can be changed using a dipswitch and data can be transferred between up to two pairs of units on the same path or parallel paths without causing interferences This equipment is specified for...

Page 4: ...Shows green when received data output is on FDX Full duplex indicator lamp red Shows red in full duplex connection Own unit CD Clear data indicator lamp red Shows red at a sufficient reception level...

Page 5: ...ator lamp RD Blinks green when the received data output is ON 8 Link indicator lamp LINK Shows green when 10BASE T link is established 9 Full duplex indicator lamp FDX Shows green when 10BASE T link i...

Page 6: ...e near a magnet motor or other devices that generate a strong magnetic field or an inverter or another devices or electric wire that generate a strong noise 5 A place where the sunlight or candescent...

Page 7: ...n normally communicate throughout the communication area after adjustment of the optical axis according to section 9 Adjustment of the Optical Axis Example 1 Type A Type A Type B Type B 0 5 m or more...

Page 8: ...t connected 8 Transmission output and reception input may be exchanged according to the connected cable AutoMDIX function Polarity of reception input may be exchanged according to the connected signal...

Page 9: ...er or external device 2 For power supply use one conforming to the specification of this machine 3 For the load of aux output connect one within the output rating 30VDC 50mA of this machine When conne...

Page 10: ...ems so that the communication mode of Full duplex Half duplex may conform to the device connected in the receiving side across the optical transmitter Special care must be taken when connecting to the...

Page 11: ...or more First adjust by referring to the display of reception level on the receiving unit 3 Make further fine adjustment until the reception level indicator lamps on the receiving unit show green up t...

Page 12: ...tervals are automatically adjusted between the units in case of buffer overflow When connecting the unit activate the auto negotiation function Action 4 Use a protocol such as TCP to retransmit the lo...

Page 13: ...ity cleaning or beam adjustment required CD only CD or more ON OFF The same with 1 Interrupted cleaning or beam adjustment required Off Off OFF OFF Off CD or more Off OFF OFF CD or more Affected by ex...

Page 14: ...within 100 m Note 2 For power wire use electric wire of 0 3 mm2 or more Extension of power wire shall be within 50 m if power voltage is 24VDC Note 3 Voltage between DL COM or ALM COM shall be 30VDC o...

Page 15: ...wer to the equipment Data cannot be transferred for further 2 sec or so because of auto negotiation when such auto negotiation is effective 3 Optical axis adjustments Do not fail to adjust optical axi...

Page 16: ...4 Ethernet connector 1 RJ45 Clear data indicator lamp receiving unit 5 CD LEVEL1 4 Mounting seat 1 Communication indicator lamp 4 SD RD LINK FDX Channel indication limp 1 CH Mounting fixture 2 ABS res...

Page 17: ...e Machinery Division Kamiya Factory TOYO ELECTRIC CORP Electric Machinery Div Head Office Hikisawa 1 39 Kamiya cho Kasugai Aichi Japan 480 0393 Kamiya Plant TEL 0568 88 1181 FAX 0568 88 3086 Tokyo Off...

Page 18: ...tion of consumption current correction of pin arrangement of aux Output Development 2007 04 06 A power supply an assistance output connector model change address change Development 2007 11 28 Change C...

Reviews: