Pneumatic press PFHL
/
PFHW
18
OM 45.PFHL-PFHW.201803.en
Mounting the path measuring
(option)
Unscrew the cover of the press head (
9
).
Remove the pin (
10
): For this purpose un-
screw the lock washer and remove the pin
from the fixing device. Lower the rods to the
front to get more space for mounting the
travel sensor.
Place the travel sensor (
1
) on the provided lo-
cation of the press head. Pay attention to a
careful threading of the rods of the path travel
sensor.
Fasten the connecting flange (
8
) of the travel
sensor to the press head using the three
screws (
7
).
Position the threaded rod of the travel sensor
(
1
) and fasten it on the ram using the hexagon
nut M 4.
Screw on the holding device (
3
) with the two
screws M 5x10 (
2
) to the side of the press
head. After this, fasten the holding device
with the help of the second screw M 5x10 to
the bottom side of the press head.
Place the plug (
4
) in the mounting clip (
5
) and
screw the clip with screws M 4x20 (
5
) to the
holding device (
3
) using the two upper bore
holes.
Connect plug (
4
) with the provided output de-
vice using an appropriate cable.
Information on travel measuring
is given in the corresponding chap-
ters of the operating manual of the
pressing monitor, for example EPW
(accessories).
8 9
8
2
3
5
4
2
7
1
10
7
1