Pneumatic press PFHL / PFHW
OM 45.PFHL-PFHW.201803.en
17
Assembly of the accessories
Mounting the stroke counter (option)
Separate the coupler (
4
) on the counter-side
from the plug (
5
).
Remove the screw provided on the counter
connection (1) of the pneumatic cylinder.
Screw the pressure switch (
2
) in the counter
connection (
1
) on the pneumatic cylinder.
Mount the counter housing (
3
) to the provided
location on the press head using the two
cheese head screws M 5x12 (
6
).
Connect plug (
5
) with the coupler (
4
).
Mounting the force sensor (Option)
Screw the holding device (
2
) with the two
screws M 5x10 (
1
) to the side of the press
head.
Dismount the existing tool holding fixture (if
already mounted).
Screw the tool holding fixture and the force
sensor (
7
) on the press ram o the press.
Fasten the black clamp (
6
) with screw M 4x8.
Plug the angle plug (
8
) in the plug of the force
sensor.
For strain relief, clamp the cable into the black
clampFor strain relief, jam the cable into the
black clamp..
Place the straight plug (
3
) in the mounting clip
(5)
and screw the clip with screws M 4x20 (
4
)
to the holding device (
2
) using the two lowest
bore holes.
Connect plug (
3
) with the provided process
control system using an appropriate cable.
Information on force measuring
is given in the corresponding chap-
ters of the operating manual of the
pressing monitor, for example EPW
(accessories).
1
2
3
4
5
6
1
2
3
4
5
4
6
7
8
Summary of Contents for FinePress PFHL 008.002
Page 2: ...Pneumatic press PFHL PFHW 2 OM 45 PFHL PFHW 201803 en ...
Page 30: ...Pneumatic press PFHL PFHW 30 OM 45 PFHL PFHW 201803 en ...
Page 31: ......
Page 32: ......