Error
Possible reason
Solution
Display: „Stop-button released“
stop-button not connected or not
bridged
Stop-button (Kl. ) connect or bridge >
use status display for help
Display: „Photocell released“
photocell interrupted
check correct connection hence
remove obstacle > use status dispaly
for help
Display: „MCE released“
main safety edge interrupted or hot-
wired
check correct connection hence
remove obstacle > use status dispaly
for help
Display: „SCE released“
side safety edge interrupted or hot-
wired
check correct connection hence
remove obstacle > use status dispaly
for help
Display: „Motor monitoring“
no motor movement because of an
obstacle in the way or because the
thermic pill has been activated
Remove obstacle or check if gate can
be moved easily by hand
Display: „Frequency converter“
cut off power supply, wait 1min. and
then switch on again - if this is not
the solution please contact service
technician
Display: „photocell test negative“
interruption or hot-wired photocell
check correct connection hence
remove obstacle > use status dispaly
for help
Display: „Low Voltage“
undervoltage
check supply line
Display: „Modul offline“
Control does not recognize limit switch
module
Check the connection control / limit
switch module
No reaction when giving an impulse
no line voltage hence
safety fuse broken
check line voltage as well as safety
fuses
error of transmitter/control device/im-
pulse button,
e.g. transmitter not programmed
check transmitter/control device,
e.g. program transmitter and
check battery
8. Troubleshooting guide
Sliding gate operator TPS 60 PRO
• Installation, connection, adjustments, putting into operation, and servicing may only be carried out by
trained professionals in full accordance with these installation- and operating instructions.
• The packaging materials (cardboard, plastic, EPS foam parts and filling material etc.) have to be properly dis
-
posed of in accordance with the applying recycling- and environmental procection laws. They may be hazardous
to children and therefore have to be stored out of children´s reach.
• The product is not suitable for installation in explosion-hazardous areas.
• The product may only be used in accordance with its original purpose, for which it has been exclusively designed,
and which is described in these installation and operating instructions. It is essential to instruct children about
the risks. The TOUSEK Ges.m.b.H. rejects any liability if the product is used in any way not fully conforming to
its original purpose as stated herein.
• All electrical installations have to be made in full conformity with the applying rules and laws (e.g. using a fault
current circuit breaker, proper grounding etc.).
• An all-pole disconnecting main switch with a contact opening-gap of minimum 3 mm has to be foreseen.
• The electric motor heats up during operation. Therefore the device should only be touched after it has cooled
off.
• After installation the proper function of the gate facility and the safety devices has to be checked!
• The installer has to inform the user about all aspects of the automatic operation of the complete gate facility,
as well as about emergency operation. The installer further has to supply to the user all instructions relating to
the safe operation of the gate facility. The installation and operating instructions also have to be handed over
to the user.
Important notes after installation