tousek
/ EN_TPS-60-PRO_05 / 25. 03. 2020
- 23 -
Function
K1
K2
Gate status
1
Gate in CLOSE position
1
0
Gate in OPEN position
0
1
2
Gate in CLOSE position
0
0
Gate opens/closes
0
1
Gate stopped or error
1
0
Gate in OPEN position
1
1
0 = signal contact opened 1= signal contact closed
Control lamp
• you can connect a control
lamp to the terminals 70/71
(
24V, max. 2W
)
Signal contacts
•
max. contact load: 1A 24Va.c./d.c.
Signal lamp
• A signal lamp can be connected
to the terminals
X1: 10/11
(230V, max. 100W).
Light / Lamps
Connections and adjustments
Pre-alert OPEN
(Photocell: terminals X1: 10/11)
Light/lamps
turned off
1–30s adjustable:
Before each opening movement the
signal lamp/ flashing light is activated for the adjusted
time.
Pre-alert CLOSE (
Photocell: terminals X1: 10/11)
turned off
1–30s adjustable:
Before each closing movement the
signal lamp/ flashing light is activated for the adjusted time.
Control lamp
(terminals X1: 70/71)
Light/lamps
llluminates at opening/closing:
The pilot lamp output
is activated during opening- and closing movement.
Flashing slowly/illuminates/flashing
:
The pilot lamp
output is activated as follows: During opening the pilot
lamp flashes slowly. During pause time, in opened posi
-
tion or when the gate stops it is illuminated. During the
closing movement it flashes rapidly. If the gate is closed,
the pilot lamp expires
Illuminated when gate is open:
Pilot lamp is illuminated
as soon as the gate has reached end position open
Warning
•
Before connection works please turn off the main power switch !
•
Follow safety rules
(see page 10)
!
Signal contacts
(Signal contact K1: Kl. X1: 90/91, signal contact K2: Kl. X1: 92/93 )
Light/lamps
Gate status 1:
with the two potential-free signal
contacts K1 and K 2, the gate end positions (limits) can be
evaluated.
Gate status 2:
with the two potential-free signal contacts
K1 and K2, the gate end positions (limits), the gate move-
ment as well as a gate stop outside of the end positions
can be evaluated.
11
10
X1
71
70
+
–
X1
93
92
91
90
signal contact K2
signal contact K1
X1