tousek
/ EN_ST-64_02 / 25. 03. 2020
- 19 -
Warning
•
Before taking off the housing cover the
main switch has to be turned off !
•
Follow safety instructions
(
page 6)
!
Important: Notes regarding
connection of a flashing light
•
Attention: Before carrying out
connection works, the power
supply of the facility has to be
turned off
• A flashing light with 230V, max.
40W can be connected at the
terminals 10/11.
Prewarning OPEN
(terminals KL1 10/11)
Light / Lamps
OFF
1–30s adjustable:
before each opening movement the flashing light is activated for the adjusted time.
Prewarning CLOSE
(terminals KL1 10/11)
Light / Lamps
OFF
1–30s adjustable:
before each closing movement the flashing light is activated for the adjusted time.
The following options, marked with
in the menu are only valid for
ST 64A
in combination with the traffic
light control unit STA 11.
Green phase
20s (factory setting)
Light / Lamps
5–120s adjustable [increment: 1]:
duration of green phase.
Clearance time
5s (factory setting)
Light / Lamps
1–60s adjustable [increment: 1]:
time to leave the traffic light intermediate area.
Traffic light gate CLOSED
Light / Lamps
OFF:
red traffic light does not illuminate in closed position.
Constant red:
red traffic light illuminates also in closed position.
Traffic light logic
Light / Lamps
both sides green:
both traffic lights illuminate in open position GREEN, regardless of which side has been given the
green request.
one side green:
only the traffic light illuminates in open position GREEN, from the side from where the green request
has been requested.
The following two menu points can only be selected if the menu point additional menu is adjusted to „Courtyard-/Control
lamp“ (hence shown on display).
Courtyard lamp
(
Description add. modules
page 20
)
Light / Lamps
OFF
5–950 adjustable:
at the courtyard lamp output an external lamp can be connected (e.g. garden lamp), which can be
turned on for each opening command for the duration of adjusted time.
Control lamp
(
Description add. modules
page 20
)
Light / Lamps
illuminates during open and close:
The pilot lamp output is activated during opening- and closing movement.
blinks slowly/illuminates/blinks:
The pilot lamp output is activated as follows: During opening the pilot lamp flashes
slowly. During pause time, in opened position or when the gate stops it is illuminated. During the closing movement
it flashes rapidly. If the gate is closed, the pilot lamp expires
illuminates in open position:
Pilot lamp is illuminated as soon as the gate has reached end position open.
Light / Lamps
Connections and adjustments
11
10
KL1