Error
possible reason
solution
no reaction after emitting a command
mains voltage missing or
fuse F1 defective
control of mains voltage as well as
of fuse F1
Display: error stop button
check if stop button is connected or
bridged properly
relays on control board switch but
motor does not run
connection between motor and
control unit defective
check supply lines
gate opens but does not close
photocell interrupted
check positioning and functions of
photocells
AR system actuated
check force and sensor adjustment
safety sensing edge 1 or 2 actuated
adjustment of safety sensing edges
wrong
remove obstacle or check the function
via status display
no function of radio receiver
radio receiver plugged in wrongly
check installation
see chapter „connection of radio
receiver“
no / wrong connected antenna
check antenna connection
radio transmitter not programmed
program radio transmitter
error message „no learned way“
sensors or motors not connected
correctly or capacitor not connected
check connections and wiring
according to manual
9. Troubleshooting guide
Swing gate control unit ST 64 (A)