<Indicating the urinal is being used>
•
AC type: Lights up
•
Alkaline battery type: Does not light up
<Indicating interval discharge pipe flush is operating>
•
AC type: Flashes
•
Alkaline battery type: Flashes
<Indicating "e-water+" cleaning is operating>
•
e-water+ type: Flashes
<Indicating part replacement for "e-water+">
•
e-water+ type: Flashes quickly
* If you see quick flashing, contact your installer or seller.
The water volume may be increased temporarily to
reduce dirt adhesion on the trap.
<Indicating battery is discharged>
•
Alkaline battery type: Flashes (in 2-second cycles)
<Indicating the power supply is turned on (10 minutes
only)>
•
AC and e-water+ types: Lights up
•
Alkaline battery type: Flashes
* For 10 minutes after replacing the battery, the detection
LED flashes during photoelectric sensor detection to
enable the detection status to be confirmed.
After this, the detection LED does not flash even
during detection.
Flushed water volume is low
CAUTION
Use the product with the shutoff valve fully open.
If the shutoff valve is partially closed, the flushing performance may drop and impair hygiene.
Detection LED lights up or flashes
In the AC type, alkaline battery type and e-water+ types, the sensor detection LED may light up
or flash. When the LED lights up or flashes, it means the following.
* If the water volume is still not appropriate, request repair from your installer or seller.
Close the shutoff valve with a flat-head
screwdriver.
Remove clogged dirt from the mesh of the
water filter with a brush, etc.
Remove the spindle guide with a monkey
wrench and then remove the water filter.
Water does not stop
Close the shutoff valve with a flat-head screwdriver.
* Request repair from your installer or seller.
Water is not flushed (AC and e-water+ types) (continued)
Hold your hand over the detection LED.
Check the power supply to confirm that power is being supplied.
* If water is still not flushed, close the shutoff valve with a flat-
head screwdriver, and request repair from your installer or
seller.
When the detection LED does not light up while the
urinal is being used
Monkey
wrench
Spindle guide
Water filter
Flat-head screwdriver
Shutoff
valve
Open
Close
Flat-head screwdriver
Shutoff
valve
Open
Close
Detection LED
Flat-head screwdriver
Shutoff
valve
Open
Close
16
17
W
ha
t t
o
D
o
?