Replacing the Battery 

(Alkaline Battery Type)

Preliminary notes on replacing the battery

If the battery inside the battery box is drained, the unit will 
flash in 2-second cycles. When it switches to 4-second 
cycles, the flushing function will stop.

Battery replacement method

WARNING

Prohibited

Use only alkaline batteries

Using an oxyride dry-cell battery or the like may cause fire or malfunctions.

Do not pull the battery box electric wires

Doing so may disconnect the wires or terminals, or cause a malfunction or electrical 
shock.

Because the flushing function stops as soon as the photoelectric sensor starts flashing in 
4-second cycles, refer to the following instructions and replace the battery immediately.

When the photoelectric sensor starts flashing in 2-second cycles, replace the battery quickly 
with the following procedure.

Battery replacement method (continued)

Remove the battery box, then remove the 
waterproof cover.

Place the battery box inside the controller.

Remove the spent alkaline battery, replace 
the battery, then attach the waterproof cover.

Return the controller to its original 
location, then tighten the screws.

[When the replacement indicator 
(4-second cycles) is flashing]

Can be used within several seconds of connecting 
a battery.

[When the replacement indicator 
(4-second cycles) is not flashing]

 

Cannot be used for 5 minutes after connecting the battery.

 

For 10 minutes after 5 minutes have passed after 
connecting a battery, the lamp flashes during photoelectric 
sensor detection to enable the detection status to be 
confirmed. After this, the LED does not flash even during 
detection.

Remove the screws, then lower the 
controller down.

oxyride dry-cell

battery

Controller

Controller

Battery box

Battery box

Controller

Controller

Battery box

Alkaline battery

If the controller does not slide out on its own, 
use a flat-head screwdriver to lower it.

12

13

W
ha
t t

o

 D
o

?

Summary of Contents for USWN925 Series

Page 1: ...safe place for future reference Instruction Manual Table of Contents Safety Precautions 2 Part Names 5 Operation System 6 Pre flush Setting 7 Routine Maintenance 8 Periodic Inspection 11 Replacing the...

Page 2: ...oller during thunderstorms Doing so may cause electrical shock Wet hands prohibited Do not plug or unplug the connector with wet hands Doing so may cause electrical shock WARNING Do not disassemble Do...

Page 3: ...the floor with a well wrung mop or cloth Leaving such substances on the floor may cause staining or corrosion Wipe off any condensation from the surface of the urinal or other parts with a dry cloth F...

Page 4: ...Pre flush No Yes 0 3 L flush 2 Interval discharge pipe flush Yes No 24 L day When interval discharge pipe flush is set to off switch No 2 set to ON the effect of reducing urolith adhesion is no longe...

Page 5: ...ts may cover the porcelain surface and reduce the effect of the built in stain prevention technology Place a towel etc over the photoelectric sensor Photoelectric sensor stops detecting Remove the tow...

Page 6: ...or with a well wrung mop or cloth Wipe any urine that splashes out from the urinal or condensation that drops from the apparatus onto the floor with a well wrung mop or cloth Wipe any detergent or wat...

Page 7: ...ry replacement method continued Remove the battery box then remove the waterproof cover Place the battery box inside the controller Remove the spent alkaline battery replace the battery then attach th...

Page 8: ...attery type Replace the battery P 12 Flushed water does not stop Close the shutoff valve and contact your installer or seller P 16 Flushed water volume is low Dirt is clogging the water filter Clean t...

Page 9: ...shing performance may drop and impair hygiene Detection LED lights up or flashes In the AC type alkaline battery type and e water types the sensor detection LED may light up or flash When the LED ligh...

Page 10: ...rce When dirty scrub using a toilet brush etc with a neutral toilet detergent Water flushes on its own This product has the following automatic flushing functions Interval discharge pipe flush In addi...

Page 11: ...s within 650 mm of the sensor Required detection time About 5 seconds or longer not detected when less than 5 seconds Water supply pressure Minimum required water pressure dynamic 0 07 MPa Maximum wat...

Reviews: