Water is not flushed (AC and e-water+ types)

WARNING

Do not 

touch

Never touch the power terminal with your 
hands while power is being supplied

Doing so may cause an electrical shock.

When the detection LED lights up normally while 

the urinal is being used

Check that the master valve and shutoff valve are 
open.

* If water is still not flushed, close the shutoff valve with a flat-

head screwdriver, and request repair from your installer or 
seller.

* If water is still not flushed, close the shutoff valve with a flat-head 

screwdriver, and request repair from your installer or seller.

If the detection LED lights up while the urinal is not 
being used, remove any objects nearby.

Power wire connecting and disconnecting procedure

A qualified electrician should perform 
connection and disconnection of the power 
wire onto the terminal block.

Before requesting repair(check Page 5 for the part names)

Symptom

Condition

Solution

Ref. Page

Floor is wet

Condensation formed on the 
urinal has dripped onto the 
floor.

Wipe the condensation with a dry cloth and 
ventilate the toilet.

P.10

Urine splashed from the urinal 
has dripped onto the floor.

Wipe the splashed urine thoroughly with a mop or 
cloth.

P.10

Water is not 
flushed

Dirt is clogging the water filter.

Clean the water filter.

P.17

The shutoff valve is not open.

Open the shutoff valve.

P.15 to P.16

The detection LED does not light 
up during use.

AC and e-water+ types:
Check that power is being supplied.

P.15 to P.16

The detection LED is flashing
(Flashes in 4-second cycles)

Alkaline battery type:
Replace the battery.

P.12

Flushed water 
does not stop

-

Close the shutoff valve and contact your installer or 
seller.

P.16

Flushed water 
volume is low

Dirt is clogging the water filter

Clean the water filter.

P.17

The shutoff valve is only 
slightly open.

Open the shutoff valve.

P.15 to P.16

Water flushes 
on its own

Flushes even though the 
urinal is not being used.

Automatic flushing functions is being performed.

P.18

Detection LED 
lights up or 
flashes

The detection LED lights up 
during use.

AC and e-water+ types:
Designed to light up, so nothing needs to be done.

P.17

The detection LED flashes 
during use.

Designed to flash while automatic flushing functions 
is being performed, so nothing needs to be done.

P.17

Alkaline battery type:
Replace the battery.
* For 10 minutes after replacing the battery, the detection 

LED flashes during photoelectric sensor detection to 
enable the detection status to be confirmed.

P.12

There is residue on 
the bowl surface

Water is repelled from the bowl sur-
face and it is difficult for it to get wet.

Refer to “Routine Maintenance” and clean the bowl 
surface.

P.8

Troubleshooting

If you think there may be a malfunction, first check that there is no power outage or water failure. If 
these are normal, remove the upper lid and then perform an inspection according to the following 
inspection items. Check "Part Names" (Page 5) for the part locations. If the malfunction persists 
even after performing the inspection according to the inspection items or you suspect something 
abnormal, close the open/close screw of the shutoff valve and then contact the installer or seller.

Detection LED

Detection LED

Terminal block

Power wire

Flat-head screwdriver

Shutoff 
valve

Open

Close

14

15

W
ha
t t

o

 D
o

?

Summary of Contents for USWN925 Series

Page 1: ...safe place for future reference Instruction Manual Table of Contents Safety Precautions 2 Part Names 5 Operation System 6 Pre flush Setting 7 Routine Maintenance 8 Periodic Inspection 11 Replacing the...

Page 2: ...oller during thunderstorms Doing so may cause electrical shock Wet hands prohibited Do not plug or unplug the connector with wet hands Doing so may cause electrical shock WARNING Do not disassemble Do...

Page 3: ...the floor with a well wrung mop or cloth Leaving such substances on the floor may cause staining or corrosion Wipe off any condensation from the surface of the urinal or other parts with a dry cloth F...

Page 4: ...Pre flush No Yes 0 3 L flush 2 Interval discharge pipe flush Yes No 24 L day When interval discharge pipe flush is set to off switch No 2 set to ON the effect of reducing urolith adhesion is no longe...

Page 5: ...ts may cover the porcelain surface and reduce the effect of the built in stain prevention technology Place a towel etc over the photoelectric sensor Photoelectric sensor stops detecting Remove the tow...

Page 6: ...or with a well wrung mop or cloth Wipe any urine that splashes out from the urinal or condensation that drops from the apparatus onto the floor with a well wrung mop or cloth Wipe any detergent or wat...

Page 7: ...ry replacement method continued Remove the battery box then remove the waterproof cover Place the battery box inside the controller Remove the spent alkaline battery replace the battery then attach th...

Page 8: ...attery type Replace the battery P 12 Flushed water does not stop Close the shutoff valve and contact your installer or seller P 16 Flushed water volume is low Dirt is clogging the water filter Clean t...

Page 9: ...shing performance may drop and impair hygiene Detection LED lights up or flashes In the AC type alkaline battery type and e water types the sensor detection LED may light up or flash When the LED ligh...

Page 10: ...rce When dirty scrub using a toilet brush etc with a neutral toilet detergent Water flushes on its own This product has the following automatic flushing functions Interval discharge pipe flush In addi...

Page 11: ...s within 650 mm of the sensor Required detection time About 5 seconds or longer not detected when less than 5 seconds Water supply pressure Minimum required water pressure dynamic 0 07 MPa Maximum wat...

Reviews: