25
Specifi cations / Spezifi kationen / Caractéristiques / Specifi che tecniche
GB
For two
For one
Bathtub
Dimensions
1,800 mm(W) x 1,400 mm(D) x
765 mm(H)
*1
1,800 mm(W) x 1,000 mm(D) x
765 mm(H)
*1
Weight
180 kg
140 kg
Capacity
570 L to overfl ow line
370 L to overfl ow line
Material
Acrylic synthetic marble
Bathtub fi lling
Outfl ow ports
One
Bathtub fi lling fl ow rate
Max. 35 L/min (controlled by function module)
Air blower
Number of blowers
15 on the bottom of the bathtub
10 on the bottom of the bathtub
Volume of air
Max. 560 L/min (15 Total, controlled
by the function module)
Max. 420 L/min (10 Total, controlled
by the function module)
Shoulder
warmer
(cascade)
Intake ports
Two
Outfl ow ports
Two
Flow rate
Max. 38 L/min (2 Total)
HydroHands
Intake ports
Two
Outfl ow ports
Four
Flow rate
Max. 150 L/min (4 Total)
Underwater
lighting
Lighting modules
Two
Colors
Three pattern types, 10 individual colors
Shower
(Two knobs)
Uses
Cleaning the bathtub
Water
pressure
Minimum required water
pressure (when fl owing)
0.08 MPa
Maximum water pressure
(when not fl owing)
0.75 MPa
Inlet water
temperature
Hot
Please confi rm local code (below 70°C)
Cold
0-30°C (No freezing)
Connection
diameter, threads
Hot
G1/2
Cold
G1/2
Bathtub fi lling connection diameter threads
G3/4
Controller
stand
Dimensions
246 mm (W), 113 mm (D), 255 mm (H)
Weight
2.8 kg (including the controller)
Adjustable arc.
90°
Function
module
Dimensions
422 mm (W), 180 mm (D), 476 mm (H)
*2
Weight
14 kg
Rated voltage
220-240 V AC
Rated frequency
50 Hz
Rated current
7.0-8.0 A
Rated power consumption
1,400-1,600 W
Standby power consumption
8.0 W
Installation location
Indoors (locations without condensation, dampness or freezing:
not in the bathroom)
Water
pressure
Minimum required water pressure
(when fl owing)
0.20 MPa
Maximum water pressure
(when not fl owing)
0.75 MPa
Inlet water temperature
Hot
60-70°C
Cold
0-30°C (No freezing)
Connection diameter,
threads
Hot
G3/4
Cold
G3/4
Fill bathtub
G3/4
Safety device
Continuous operation prevention device, over current protection
device, ground-fault circuit interrupter (GFCI).
*1 The height of the bathtub includes the frame that supports the bathtub.
*2 The function modules external height excludes the connection ports.
Summary of Contents for NEOREST VPKZ1800E
Page 34: ...34 3 3 A 9 4 4 G 3 4 G 1 2 G 1 2 B 15 B 16...
Page 35: ...35 5 5 B 9 B 4 Adjust Anpassen R gler Regolare Lock Befestigen Verrouiller Serrare 6 6...
Page 37: ...37 9 9 B 17...
Page 48: ...48 2 2 Change mode 3 3 Change mode...
Page 50: ...50 3 3 Change mode...
Page 52: ...52 Shower Dusche Douche Doccia 1 1 00 00 00 00 10 00 2 2...
Page 60: ...60 5 5 A 12 6 6 A 13a 7 7 8 8 A 13a...
Page 61: ...61 9 9 A 14 A 10 1 10 0 1 11 1 180 360 A 15 B 12...
Page 71: ...71...