3-9
Alarm Limits
You have the ability to set
µ
FLO Alarm Limits for the parameters listed in table 3–4. There are many
purposes for setting these limits. i.e. Controlling well output, or sending digital signals.
Table 3–4 Alarm Limits
Configurable
Parameter
Default Value
Units
AGA-3 1985 AGA-3 1992
DP High Limit
2047.9688
In H2O
Yes
Yes
DP Low Limit
0
In H2O
Yes
Yes
Flow Rate High Limit
1,000,000
SCF/Hr
Yes
Yes
Flow Rate Low Limit
0
SCF/Hr
Yes
Yes
RTD High Limit
420
Degrees F
Yes
Yes
RTD Low Limit
0
Degrees F
Yes
Yes
SP High Limit
2047.9688
PSIA
Yes
Yes
SP Low Limit
0
PSIA
Yes
Yes
Reset Volume
When you Reset the volume accumulator the
µ
FLO will:
•
Store time, date and previous accumulated partial calc periods volume into the historical record file
•
Zero the remaining partial calc periods accumulations.
•
Complete all computations for the present flow file daily record.
•
Begin a new flow file daily record.
•
Zero total volume accumulator and log the event with an accumulator value before zeroing out
accumulator.
Since the
µ
FLO volume calculations are made each vol calc period, any changes
you make during the period would affect the volume calculations (such as changing
the orifice plate size) and be introduced into the calculations. To avoid introduced
errors, it is recommended that Reset Volume command be used. This command
forces the
µ
FLO to perform volume calculations for the elapsed time since a
previous volume calculation was made. A new partial period volume is added to the
volume accumulator, which is logged as an event before it is reset to zero (0).
Summary of Contents for uFLO
Page 1: ...2100890 001 AB TOTALFLOW µFLO Computer User s Manual ...
Page 6: ...iv B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 8: ...vi B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 10: ...viii B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 14: ...xii B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 16: ...1 2 FLO 6213 Figure 1 1 µFLO 6213 Dimensions ...
Page 18: ...1 4 Figure 1 3 Bottom View µFLO 6213 9 367 9 992 8 647 Figure 1 4 Bottom View µFLO 6210 ...
Page 39: ...2 9 FLO 6213 Figure 2 7 µFLO 6213 Wall Mounted ...
Page 50: ...2 20 Figure 2 13 Mounting AC Charger ...
Page 60: ...3 10 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 62: ...3 12 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 64: ...3 14 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 70: ...4 6 11 9 5 4 1 13 3 FLO 6210 12 8 7 10 2 Figure 4 2 µFLO 6210 Component Cable Locations ...
Page 71: ...4 7 1 6 FLO 6213 5 13 3 2 4 7 8 10 9 12 11 Figure 4 3 µFLO 6213 Component Cable Locations ...
Page 132: ...6 2 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...