![Total Control Systems 700-LP Series Installation, Operation & Maintenance Manual Download Page 38](http://html1.mh-extra.com/html/total-control-systems/700-lp-series/700-lp-series_installation-operation-and-maintenance-manual_1138832038.webp)
Page 38
Page 38
Assembly of Check Valve
WARNING
All internal pressure must be relieved to ZERO (0) pressure before beginning disassembly
of meter or components
CHECK VALVE ASSEMBLY
1)
Insert pressure relief valve (#2) into valve housing (#1).
2)
Slide piston ring (#4) onto valve housing (#3).
3)
Place o-ring (#6) over shaft of valve housing (#3) and up to
piston ring (#4) surface.
4)
Install spacer (#7) over shaft of valve housing (#3) and
over o-ring(#6).
5)
Insert o-ring (#5) into groove of o-ring retainer (#8).
6)
Slide o-ring retainer (#8) over shaft of valve housing (#3).
7)
Using the torque specifications, apply and tighten the nut
(#9) on the valve housing (#3.
8)
Install assembly into housing (#1) with o-ring facing pipe
threads of housing (#1).
9)
Press bearing sleeve (#12) into spring holder (#11).
10) Insert spring holder (#11) into housing (#1) with
cylinder facing pipe threads.
11) Install retaining ring (#13) into groove of housing (#1).
Summary of Contents for 700-LP Series
Page 10: ...Page 10 Meter Dimensions in Inches Millimeters...
Page 14: ...Page 14 700 20 LP Meter Assembly...
Page 16: ...Page 16 730 20 LP Vapor Eliminator Assembly...
Page 18: ...Page 18 720 20 LP Strainer Assembly...
Page 20: ...Page 20 757 20 LP Differential Valve Assembly...
Page 22: ...Page 22 782 20 LP In Line Check Assembly...
Page 45: ...Page 45 Page 45 NOTES...
Page 46: ...Page 46 Page 46 NOTES...