![Total Control Systems 700-LP Series Installation, Operation & Maintenance Manual Download Page 36](http://html1.mh-extra.com/html/total-control-systems/700-lp-series/700-lp-series_installation-operation-and-maintenance-manual_1138832036.webp)
Page 36
Page 36
Assembly of Vapor Eliminator
WARNING
All internal pressure must be relieved to ZERO (0) pressure before beginning disassembly
of meter or components
1) Using a 1/2‖ wrench or socket, remove the cover screws from vapor eliminator cover plate.
2) Remove cover plate.
3) Remove valve plate, inspect and replace as needed.
1) To remove the vapor eliminator assembly, remove the four screws and washers attaching it to the strainer.
2) Using a flathead screwdriver, remove the screws attaching reed valves to air eliminator housing.
3) Remove the two screws on the diffuser screen.
4) Slide out diffuser shaft assembly.
5) Remove the two screws attaching reed valve to the float assembly. Inspect and replace reed valves as needed.
1
2
3
1
2
3
4
5