DC Inverter U-match Series Cassette Type Unit
5
Indoor Unit Accessories
No.
Name
Appearance
Quantity
Usage
15
Bolt Assembly
4
Connect the panel and
body(only for 18k unit)
Table 3.2
Outdoor Unit Accessories
No.
Name
Appearance
Quantity
Usage
1
Drain Plug
1 or 3
To plug the unused drain
hole
2
Drainage
Connecter
or
1
To connect with the hard
PVC drain pipe
3.2 Selection of the Installation Location
!
1
The unit must be installed where strong enough to withstand the weight of the unit
and fixed securely, otherwise the unit would topple or fall off.
2
Do not install where there is a danger of combustible gas leakage.
3
Do not install the unit near heat source, steam, or flammable gas.
4
Children under 10 years old must be supervised not to operate the unit.
Decide the installation location with the customer as follows:
3.2.1 Indoor Unit
Select an installation site where the following conditions are fulfilled and that meets
your customer's approval.
(1) Obstruct should be put away from the intake or outlet vent of the indoor unit
so that the airflow can be blown through all the room.
(2) Make sure that the installation meets the requirement of the schematic
diagram of installation spaces.
(3) Select the place where can stand 4 times of the weight of the indoor unit and
would not increase the operating noise and vibration.
(4) The horizontality of the installation place should be guaranteed.
(5) Select the place where is easy to drain out the condensate water, and
connect with outdoor unit.