DC Inverter U-match Series Cassette Type Unit
15
4.2.1 Outdoor unit dimension
Fig. 4.9
Table 4.4
Unit: mm (inch)
Item
Model
A
B
C
D
E
TU18H3O
9
55(37-5/8)
395(15-1/2)
700(27-1/2)
560(22)
360(14-1/8)
TU24H3O
980(38-5/8)
425(16-3/4)
790(31-1/8)
610(24)
395(15-1/2)
TU30H3O
TU36H3O
1105(43-5/8)
440(17-3/8)
1100(43-1/4)
630(24-7/8)
400(15-3/4)
TU42H3O
960(37-3/4)
410(16-1/4)
1350(53-1/8)
570(22-1/2)
375(14-3/4)
TU48H3O
4.2.2 Condensate Drainage of the Outdoor Unit (Only for the heat pump unit)
(1) It is required to install a drain pipe for the outdoor unit to drain out the
condensate water during heating operation (only for the heat pump unit).
(2) When installing the drain pipe, apart from the drain pipe mounting hole, all
other holes should be plugged so as to avoid water leakage (only for the heat
pump unit).
(3) Installation Method: Insert the pipe joint into the hole Φ25mm (1inch) located
at the base plate of the unit and then connect the drain pipe to the pipe joint.