No.
Part name
Procedure
Remarks
#
High
pressure
switch
1. Detachment
1) Recover the refrigerant gas.
2) Carry out works of 1 of
1
.
3) Take off the inverter cover.
take off screws between the inverter
cover and the inverter box.
(CTT2T Ø4 × 10, 1 pcs.)
4) Cut the CABLE-TIE that fixate high
pressure switch lead line.
5) Take off the connector for high pressure
switch from the inverter.
6) Using a burner, take off the High
pressure switch.
High pressure swith connector
CABLE-TIE
CABLE-CLAMP
High pressure swith
Cut CABLE-TIE
- 97 -