54
–
FILE NO. SVM-12050
<How to connect remote controller for wire operation>
For indoor unit
1. Open the air inlet grille upward.
2. Securely remove two screws at the front panel.
3. Slightly open the iower part of the front panel thon
pull the upper part of the front toward you to remove
it from the rear plate as shown on figure 1 .
4. After removing the front panel, remove the display
unit and open the cover as shown on figure 2 and 3 .
5. Arrange the control wire as detail and specification
as shown on figure 4 .
6. Securely connect the control wire to terminal of
display unit board as shown on figure 5 (tighten
firmly but not over : 0.12 N·m (0.01 kgf·m).
7. Set the control wire throughout at slot on front cover
of display unit then reassembly display with main
casing by reverse process of figure 2 and 3 .
Make sure the control wire must not be pressed
by front and rear cover of display unit.
8. Set the control wire out from indoor unit same
Indoor unit
Control wire
Remote controller
portion as power supply and connecting cable as
shown on figure 6 .
9. Reassembly the indoor unit by reverse process
of 1 to 3.
Air inlet grille
Front panel
Display board
1
Display unit
2
3
For remote controller
1. Remove cover of remote controller by sliding down
and take it out.
2. If batteries are exist, please take them out. The
combination of using wire controller and batteries may
cause of batteries explosion.
3. Make hole for insert control wire by use screwdriver
break the polyester sheet as shown on figure
7
.
4. Insert control wire from rear side of remote controller
as shown on figure 8 .
5. Fix control wire which arrange as shown on figure
9
and
10
to terminal by provided screws (tighten firmly
but not over : 0.25 N·m (0.03 kgf·m).
6. Set control wire through gutter way at rear side of
remote controller as shown on figure
11
.
7. Fix provided screw (
∅
3.1 x 16L) on the wall to hang
remote controller as shown on figure
12
.
8. Mark and arrange hole for fix below screw
(
∅
3.1 x 25L) as shown on figure
12
.
9. Assembly battery cover which provided with accessory
bag then use provide screw (
∅
3.1 x 25L) to fix battery
cover together with wall as shown on figure
13
(tighten firmly but not over 0.15 N.m (0.02 kgf.m)).
10. Reassembly cover of remote controller.
Fig. 10-3-6
Fig. 10-3-7
Fig. 10-3-8
Fig. 10-3-9
* Wire size 28-22AWG
or 0.08-0.32 mm
2
Outer diameter not over 4.7 mm,
control wire length 30 m. or less.
70 mm
5 mm
4
6
Notch for wire out
Control wire
5
Terminal
Control wire
Tighten firmly
but not over
0.12 N·m (0.01 kgf·m)
Polyester sheet close hole
for insert control wire
Control wire
30 mm
10 mm
* Wire size 28-22 AWG (0.08~0.32 mm
2
)
Outer diameter not over 4.7 mm,
control wire length
3
0 m. or less.
9
Control wire
Terminal
!
Tighten fi rmly but not over
0.25 N·m (0.03 kgf·m)
7
8
2
1
3