12-
3
. Outdoor unit (
RAS-1
6J2AVSG-E)
No.
Part name
Procedures
Remarks
1
Common procedure
1. Detachment
Wear gloves for this job.
Otherwise, you may injure your hands on
the parts, etc.
1)
Stop operation of the air conditioner, and
turn off the main switch of the breaker for air
conditioner.
2)
Remove the valve cover.
(ST
2
TØ4 × 10L 2 pcs.)
•
After removing screw, remove the valve
cover pulling it downward.
3)
Remove cord clamp (ST2TØ4 × 14L 3 pcs.),
and then remove connecting cable.
4)
Remove the upper cabinet.
(ST
2
TØ4 × 10L 5 pcs.)
•
After removing screws, remove the
upper
cabinet pulling it upward.
NOTE
Screw ST1T
Screw ST2T
Upper cabinet
Valve cover
2
Front cabinet
1.
Detachment
1)
Perform step 1 in
1
.
2)
Remove the fixing screws (ST
2
TØ4 × 10L
2 pcs.) used to secure the front cabinet and
inverter cover, the screws (ST
2
TØ4 × 10L
4 pcs.) used to secure the front cabinet at
the bottom, and the fixing screws (ST
2
TØ4
× 10L 2 pcs.) used to secure the motor
base.
•
The front cabinet is fitted into the side
cabinet (left) at the front left side so pull
up the top of the front cabinet to remove
it.
2.
Attachment
1)
Insert the claw on the front left side into the
side cabinet (left).
2)
Hook the bottom part of the front right side
onto the concave section of the bottom
plate. Insert the claw of the side cabinet
(right) into the square hole in the front
cabinet.
3)
Return the screws that were removed
above
to their original positions and attach
them.
Concave section
Claw
Square
hole
Front cabinet
- 125 -