High Wall, Heat Pump Type
Service Manual
98
Toshiba
11-1-8. Cross Flow Fan
1) Perform all the steps in
11-1-1.Removing the
Front Panel and Moving Panel
and
11-1-2.
Fixing Frame Assembly
.
2) Remove the two fixing screws (10 mm) at the
left of the heat exchanger end plate, and then
remove the two fixing screws (12 mm) of the
bearing base assembly.
3) Remove the bearing base while lifting the heat
exchanger.
4) Remove the cross flow fan while lifting the heat
exchanger.
CAUTION
Check and perform items 1 and 2 in the following table.
Screws (12 mm)
Bearing
base
Screws
(10 mm)
Heat
exchanger
A
B
1
Keep 27mm distance between the support shaft at the rear
centre of the unit and the immediate right joint-section of the
cross flow fan.
2
Check that the fan motor shaft end
projects by 9 mm above
the screw boss of the cross flow fan.
If the motor shaft end is below the screw boss, the cross flow
fan may have been assembled improperly. Check again
whether the cross flow fan have been assembled properly.
3
Be sure to tighten the hexagon socket set screw so that it
touches the D-cut surface of the fan motor shaft.
27mm
Detail A
The support shaft
at the rear centre of the unit
Detail B
Fan motor shaft
9mm
Set screw of the cross flow fan
+00A08-010_01EN_SVM_HighWallHeatPump.book Page 98 Wednesday, March 4, 2009 11:22 AM