TS-L532A (SD-R6472) Rev.1.1
8 / 28
3.3.2. Installation
(1) The surface where the drive is fixed must be sufficiently flat, and it is recommended that any
unevenness is within 0.2mm enough. Be sure not to apply excessive force to the drive, as this
may deform it, etc.
(2) Leave as much spaces as possible around the sides of and above the drive, so that it does not
come into contact with any other equipment, even if subjected to vibration, shock, etc.
The recommended amount of clearance space for equipment with a thickness of 12.9 mm
(maximum) is 0.5 mm or more vertically. It is also recommended to leave a space of 0.8 mm or
more around the front bezel in all directions.
(3) Special care must be taken in respect of heat. When installing the drive, keep the ambient
temperature below 50 ºC by ventilating and shutting off any hot air from peripheral equipment.
(4) Do not use force exceeding the restricted range on the top and the bottom covers of the drive.
(Refer to Figure 2 for details of the restricted range for the top cover. For the bottom cover, force
applied must be 2N or less across the whole area.)
Figure 2 Restricted force range for the top cover
(5) Install this drive in correct structure and in a proper manner, since EMC (Electromagnetic
Compatibility) characteristics are influenced by the method of installation.
R46
R59
R63
2 N
1 N
0.5 N
Do not add
the force.
37
24
5.4
7
11
64
70
74
128
129
Summary of Contents for R6472 - DVD±RW Drive - IDE