No.
Part name
P
rocedure
s
Remarks
Vertical louver
assembly
9
10
1) Follow the procedure item 3 and 8 .
2) Remove 2 fixing screws from the base
vertical louver then remove the vertical louver
assembly from the body back.
Vertical louver
Screw
Screw
Cover motor VT
assembly
1) Follow the procedure item 3 , 8 and 9 .
2) Remove 4 fixing screws from the body back.
then remove cover motor VT assembly from
rear side of main unit.
Screws
Screws
Cover motor VT
assembly (L)
Cover motor VT
assembly (R)
Back body
Heat exchanger
Bearing base
Cross flow fan
Bearing base
1) Follow the procedure item 3 .
2) Remove 4 fixing screws from the bearing
base, then remove it from the main unit.
11
<Caution at assembling>
-- If the bearing is out from the housing, push it
into the specified position, then incorporate it
in the main unit.
Bearing base
Bearing
Cross flow fan
Heat exchanger
Cross flow fan
12
1) Follow the procedure item 9 and
11
.
2) Loosen the set screw of the cross flow fan.
Vertical louver Hexagon screw driver
Cross flow fan
3)) Lift up the heat exchanger follow the figure.
Pull out the left hand side until the cross flow
fan released from the shaft of the fan motor
and then pull out the lower side of heat
exchanger follow the figure.
<To re-installation>
1) To incorporate the fan motor and the motor
into the position in the following figure.
- Install the cross flow fan so that the right
end of the 1st joint from the right of the
Cross flow fan is keep 3.5mm from closed
wall of the main unit.
- 111 -