No.
18
19
20
21
Item
MEMORY operation
DC motor
Save operation
Outline of specifications
Start the air conditioner in the operation mode which
you want the remote control to memorize.
(1) Press this button briefly to standby memorizing the
setting.
All the icons currently displayed except for the clock
display and mark flashes.
(2) Press and hold the MEMO button for more than 3
seconds while the display flashes.
The mark is indicated and the setting is memorized.
• If you do not press the MEMO button within 3
seconds or if you press another button, the
MEMORY setting is cancelled.
• Operation modes which can be memorized with
the MEMO button are MODE, Temperature, FAN,
TIMER and Hi POWER.
PRESET operation
To operate the air conditioner with the setting memo-
rized by the MEMO button.
(1) Press the PRESET button. The setting memorized
with the MEMO button will be indicated and the air
conditioner operates with regards to the setting.
• The lamp (green) on the display panel of the
indoor unit goes on, and operation starts after
approximately 3 minutes.
• Initial setting:
MODE
: AUTO
Temperature : 22
(1) When the fan stator, positioning is performed for the
starter and the rotor. (Vibrate slightly)
(2) DC motor operates according to the command from
the indoor controller.
(Note)
If the fan lock was detected, the operation of the indoor
unit stops and the error is displayed.
(1) The save operation starts when
SAVE
button on the
remotecontroller is turned on.
(2) While the save operation is performed,
segment
goes on the screen of the wired remote controller.
(3) The request capacity ratio is restricted to approx.
75% during save operation.
(4) If the save operation was validated, the contents are
held during the operation stop, the operation mode
change and the resetting of power supply. Therefore
the operation at the next time also will be activated
with “Save operation is valid”
Remarks
Check code [P12]
RBC-AMT32E
SWING
FAN
FIX
QUIET
COMFORT
SLEEP
3
2
1
SWING
FAN
FIX
QUIET
COMFORT
SLEEP
1
Hi POWER
Hi POWER
FILE NO. SVM-17045
- 23 -