13
Electrical Connections
E Box layout
Power Lines Schematic
Fuses (AC250V T30A):
F1&F2:
Hot water cylinder electric heater supply
F3&F4:
Back up heater 1 (3kW)
F5&F6:
Back up heater 2 (3kW)
F7&F8:
Back up heater 3 (3kW)
Fuses (AC250V T3.15A)
F9&F10:
A rated water pump
PCB’s:
MCC-1214:
TCB-PCMO3E (optional input PCB)
MCC-1217:
TCB-PCIN3E (optional output PCB)
MCC-1431:
Relay PCB for control of second
water pump, 2 way valve and booster heater
outputs
MCC-1511:
Main hydro unit control / interface
PCB
Contactors & Relays:
RY01:
Interlock relay – flow switch / back up
heater circuit
RY02:
Power contactor for back up heater supply
RY03:
Control relay for back up heater s 2 & 3
operation
RY04:
Power contactor for back up heater supply
RY05:
Power contactor for hot water cylinder
electric heater supply
RY06:
Control relay for mixing valve (2 zone)
operation