The BMS-IFMB0AWR-E interface enables the complete and natural integration of TOSHIBA air
conditioners in Modbus RTU (RS-485) networks.
The BMS-IFMB0AWR-E is compatible with the TOSHIBA ESTIA AW-LINK lines.
•
Reduced dimensions 90 (93) x 53 x 58 mm.
•
Quick and easy installation.
Mounting on DIN rail, wall
•
No external power supply required.
•
Direct connection to Modbus RTU (RS-485) networks.
BMS-IFMB0AWR-E is a Modbus slave unit.
•
Direct connection to the hydro unit.
•
Configuration of both integrated DIP switches and Modbus RTU.
•
Total control and monitoring.
•
Real states of the internal variables of the hydro unit.
•
Enables the simultaneous use of the remote control and the Modbus RTU.
TOSHIBA MB interface BMS-IFMB0UEW-E
User Manual
4
-EN
1. Presentation
The BMS-IFMB0UEW-E interface allows a complete and natural integration of Toshiba Air to Water
heat pump into Modbus RTU (RS-485) networks.
The BMS-IFMB0UEW-E is compatible with the Toshiba ESTIA AW-LINK and TU2C-LINK lines.
Reduced dimensions. 90(93) x 53 x 58 mm.
Quick and easy installation.
Mountable on DIN rail, wall
External power not required.
Direct connection to Modbus RTU (RS-485) networks.
BMS-IFMB0UEW-E is a Modbus slave device.
Direct connection to the Hydro unit.
Configuration from both on-board DIP-switches and Modbus RTU.
Total Control and Supervision.
Real states of the Hydro unit's internal variables.
Allows using simultaneously the Remote Controller and Modbus RTU.
TOSHIBA
BMS-IFMB0UEW-E
RS-485
A+
A
B
B-
TOSHIBA
BMS-IFMB0UEW-E
RS-485
A+
A
B
B-
TOSHIBA
BMS-IFMB0UEW-E
RS-485
A+
A
B
B-
Up to 63
Hydro
units
Modbus RTU
master device
SCADA
PLC
DDC
BMS
HMI
Controller
etc
BMS-IFMB0UEW-E
Modbus RTU RS-485
network
BMS-IFMB0UEW-E
BMS-IFMB0UEW-E
BMS-IFMB0UEW-E
BM
S-IFMB0UEW
-E
MODBUS MODULE
Summary of Contents for ESTIA R32 HWT-1101F21MT6W-E
Page 1: ...APPENDIX R32 VERSION 1 0 Manual for ESTIA air to water heat pump ...
Page 3: ...8 11 14 16 h LI 1 Ph LI 1 Ph LI h LI 1 Ph LI 1 Ph LI 3 Ph 1 Ph 3 Ph 3 Ph h h 1 Ph 3 Ph 3 Ph ...
Page 8: ......
Page 26: ...26 I TOSHIBA 26 I TOSHIBA SCHEMA 1 0 ...
Page 27: ...TOSHIBA I 27 TOSHIBA I 27 SCHEMA 1 1 ...
Page 28: ...28 I TOSHIBA 28 I TOSHIBA SCHEMA 2 0 ...
Page 29: ...TOSHIBA I 29 TOSHIBA I 29 SCHEMA 2 1 ...
Page 30: ...30 I TOSHIBA 30 I TOSHIBA SCHEMA 3 0 ...
Page 31: ...TOSHIBA I 31 TOSHIBA I 31 SCHEMA 3 1 ...
Page 32: ...32 I TOSHIBA 32 I TOSHIBA SCHEMA 4 0 ...
Page 33: ...TOSHIBA I 33 TOSHIBA I 33 SCHEMA 4 1 ...
Page 34: ...34 I TOSHIBA 34 I TOSHIBA SCHEMA 5 0 ...
Page 35: ...TOSHIBA I 35 TOSHIBA I 35 SCHEMA 6 0 ...
Page 36: ...36 I TOSHIBA 36 I TOSHIBA SCHEMA 7 0 ...
Page 37: ...TOSHIBA I 37 TOSHIBA I 37 WIRING DIAGRAM 230 V ...
Page 38: ...38 I TOSHIBA 38 I TOSHIBA WIRING DIAGRAM 400V ...
Page 41: ...APPENDIX R32 VERSION 1 0 Manual for ESTIA air to water heat pump ...