4.HYDRO UNIT
Engineering Data book
55
Cooling capacity and power input
* Cooling capacity and power input are the data at rated compressor operating frequency of rated condition 1
* Power input does not include water pump power.
* Cooling capacity and power input are measured in accordance with EN14511.
Capacity (kW)
LWT (°C)
7
10
13
15
18
TO
(°C)
20
12.88
14.10
15.29
16.49
17.68
27
13.44
14.72
15.96
17.20
18.45
30
12.95
14.18
15.38
16.58
17.77
35
12.11
13.26
14.38
15.05
16.20
40
10.87
11.90
13.08
13.87
14.75
43
10.11
11.14
12.29
13.09
14.07
Power input (kW)
LWT (°C)
7
10
13
15
18
TO
(°C)
20
3.12
3.21
3.28
3.31
3.35
27
3.93
4.04
4.13
4.22
4.31
30
4.12
4.23
4.33
4.42
4.51
35
4.42
4.55
4.65
4.70
4.80
40
4.74
4.86
4.98
5.05
5.16
43
4.93
5.09
5.24
5.31
5.47
EER
LWT (°C)
7
10
13
15
18
TO
(°C)
20
4.13
4.40
4.67
4.98
5.28
27
3.42
3.65
3.87
4.08
4.28
30
3.14
3.35
3.55
3.75
3.94
35
2.74
2.92
3.10
3.20
3.38
40
2.30
2.45
2.63
2.75
2.86
43
2.05
2.19
2.35
2.47
2.57
TO
:
Outdoor temperature (DB°C)
LWT
:
Leaving water temperature (°C)
Summary of Contents for ESTIA HWS-1501CSHM3-E
Page 3: ...2 1 INTRODUCTION ...
Page 7: ...6 2 SYSTEM OVERVIEW ...
Page 11: ...10 3 SYSTEM SPECIFICATION ...
Page 60: ...59 5 OUTDOOR UNIT ...
Page 79: ...78 6 HOT WATER CYLINDER ...
Page 85: ...84 7 HYDRO UNIT INSTALLATION MANUAL ...
Page 132: ... 131 7 HYDRO UNIT INSTALLATION MANUAL Engineering Data Book MEMO ...
Page 133: ...132 8 OUTDOOR UNIT INSTALLATION MANUAL ...
Page 162: ... 161 8 OUTDOOR UNIT INSTALLATION MANUAL Engineering Data book MEMO ...
Page 163: ...162 9 OWNER S MANUAL ...
Page 179: ...Air to Water Heat Pump Engineering Data Book Oct 2010 ...